In science and engineering, the parts-per notation is a set of pseudo units to describe small values of miscellaneous dimensionless quantities, e.g. mole fraction or mass fraction. Since these fractions are quantity-per-quantity measures, they are pure numbers with no associated units of measurement. Commonly used are ppm (parts-per-million, 10–6), ppb (parts-per-billion, 10–9), ppt (parts-per-trillion, 10–12) and ppq (parts-per-quadrillion, 10-15).
Contents
|
Parts-per notation is often used describing dilute solutions in chemistry, for instance, the relative abundance of dissolved minerals or pollutants in water. The unit “1 ppm” can be used for a mass fraction if a water-borne pollutant is present at one-millionth of a gram per gram of sample solution.
Similarly, parts-per notation is used also in physics and engineering to express the value of various proportional phenomena. For instance, a special metal alloy might expand 1.2 micrometers per meter of length for every degree Celsius and this would be expressed as “α = 1.2 ppm/°C.” Parts-per notation is also employed to denote the change, stability, or uncertainty in measurements. For instance, the accuracy of land-survey distance measurements when using a laser rangefinder might be 1 millimeter per kilometer of distance; this could be expressed as “Accuracy = 1 ppm.”[1]
Parts-per notations are all dimensionless quantities: in mathematical expressions, the units of measurement always cancel. In fractions like “2 nanometers per meter” (2 nm/m = 2 nano = 2 × 10−9 = 2 ppb = 2 × 0.000000001) so the quotients are pure-number coefficients with positive values less than 1. When parts-per notations, including the percent symbol (%), are used in regular prose (as opposed to mathematical expressions), they are still pure-number dimensionless quantities. However, they generally take the literal “parts per” meaning of a comparative ratio (e.g., “2 ppb” would generally be interpreted as “two parts in a billion parts”).[2]
Parts-per notations may be expressed in terms of any unit of the same measure. For instance, the coefficient of thermal expansion of a certain brass alloy, α = 18.7 ppm/°C, may be expressed as 18.7 (µm/m)/°C, or as 18.7 (µin/in)/°C; the numeric value representing a relative proportion does not change with the adoption of a different unit of measure.[3] Similarly, a metering pump that injects a trace chemical into the main process line at the proportional flow rate Qp = 125 ppm, is doing so at a rate that may be expressed in a variety of volumetric units, including 125 µL/L, 125 µgal/gal, 125 cm3/m3, etc.
Ppm is also a measure of the chemical shift in nuclear magnetic resonance spectroscopy and represents difference of the frequency in parts per million from the reference frequency (signal).
Although the International Bureau of Weights and Measures (an international standards organization known also by its French-language initials BIPM) recognizes the use of parts-per notation, it is not formally part of the International System of Units (SI).[2] Note that although “percent” (%) is not formally part of the SI, both the BIPM and the ISO take the position that “in mathematical expressions, the internationally recognized symbol % (percent) may be used with the SI to represent the number 0.01” for dimensionless quantities.[2][5] According to IUPAP, “a continued source of annoyance to unit purists has been the continued use of percent, ppm, ppb, and ppt.”[6]. Although SI-compliant expressions should be used as an alternative, the parts-per notation remains nevertheless widely used in technical disciplines. The main problems with the parts-per notation are the following:
Because the named numbers starting with a “billion” have different values in different countries, the BIPM suggests avoiding the use of “ppb” and “ppt” to prevent misunderstanding. In the English language, named numbers have a consistent meaning only up to “million”. Starting with “billion”, there are two numbering conventions: the “long” and “short” scales, and “billion” can mean either 109 or 1012. The U.S. National Institute of Standards and Technology (NIST) takes the stringent position, stating that “the language-dependent terms [ . . . ] are not acceptable for use with the SI to express the values of quantities.”[7]
Although "ppt” usually means "parts per trillion", it occasionally means “parts per thousand”. Unless the meaning of "ppt" is defined explicitly, it has to be guessed from the context.
Another problem of the parts-per notation is that it may refer to either a mass fraction or a mole fraction. Since it is usually not stated which quantity is used, it is better to write the unit as kg/kg, or mol/mol (even though they are all dimensionless).[8] For example, the conversion factor between a mass fraction of 1 ppb and a mole fraction of 1 ppb is about 4.7 for the greenhouse gas CFC-11 in air. The usage is generally quite fixed inside most specific branches of science, leading some researchers to draw the conclusion that their own usage (mass/mass, mol/mol or others) is the only correct one. This, in turn, leads them to not specify their usage in their publications, and others may therefore misinterpret their results. For example, electrochemists often use volume/volume, while chemical engineers may use mass/mass as well as volume/volume. Many academic papers of otherwise excellent level fail to specify their usage of the parts-per notation. The difference between expressing concentrations as mass/mass or volume/volume is quite significant when dealing with gases and it is very important to specify which is being used.
SI-compliant units that can be used as alternatives are shown in the chart below. Expressions that the BIPM does not explicitly recognize as being suitable for denoting dimensionless quantities with the SI are shown in underlined green text.
NOTATIONS FOR DIMENSIONLESS QUANTITIES | ||||
---|---|---|---|---|
Measure | SI units |
Named parts-per ratio |
Parts-per abbreviation |
Value in scientific |
A strain of… | 2 cm/m | 2 parts per hundred | 2%[9] | 2 × 10−2 |
A sensitivity of… | 2 mV/V | 2 parts per thousand | 2 ‰ | 2 × 10−3 |
A sensitivity of… | 0.2 mV/V | 2 parts per ten thousand | 2 ‱ | 2 × 10−4 |
A sensitivity of… | 2 µV/V | 2 parts per million | 2 ppm | 2 × 10−6 |
A sensitivity of… | 2 nV/V | 2 parts per billion | 2 ppb | 2 × 10−9 |
A sensitivity of… | 2 pV/V | 2 parts per trillion | 2 ppt | 2 × 10−12 |
A mass fraction of… | 2 mg/kg | 2 parts per million | 2 ppm | 2 × 10−6 |
A mass fraction of… | 2 µg/kg | 2 parts per billion | 2 ppb | 2 × 10−9 |
A mass fraction of… | 2 ng/kg | 2 parts per trillion | 2 ppt | 2 × 10−12 |
A mass fraction of… | 2 pg/kg | 2 parts per quadrillion | 2 ppq | 2 × 10−15 |
A volume fraction of… | 5.2 µL/L | 5.2 parts per million | 5.2 ppm | 5.2 × 10−6 |
A mole fraction of… | 5.24 µmol/mol | 5.24 parts per million | 5.24 ppm | 5.24 × 10−6 |
A mole fraction of… | 5.24 nmol/mol | 5.24 parts per billion | 5.24 ppb | 5.24 × 10−9 |
A mole fraction of… | 5.24 pmol/mol | 5.24 parts per trillion | 5.24 ppt | 5.24 × 10−12 |
A stability of… | 1 (µA/A)/min. | 1 part per million per min. | 1 ppm/min. | 1 × 10−6/min. |
A change of… | 5 nΩ/Ω | 5 parts per billion | 5 ppb | 5 × 10−9 |
An uncertainty of… | 9 µg/kg | 9 parts per billion | 9 ppb | 9 × 10−9 |
A shift of… | 1 nm/m | 1 part per billion | 1 ppb | 1 × 10−9 |
A strain of… | 1 µm/m | 1 part per million | 1 ppm | 1 × 10−6 |
A temperature coefficient of… | 0.3 (µHz/Hz)/°C | 0.3 part per million per °C | 0.3 ppm/°C | 0.3 × 10−6/°C |
A frequency change of… | 0.35 × 10−9 ƒ | 0.35 part per billion | 0.35 ppb | 0.35 × 10−9 |
Note that the notations in the “SI units” column above are all dimensionless quantities; that is, the units of measurement factor out in expressions like “1 nm/m” (1 nm/m = 1 nano = 1 × 10−9) so the quotients are pure-number coefficients with values less than 1.
Because of the cumbersome nature of expressing certain dimensionless quantities per SI guidelines, the International Union of Pure and Applied Physics (IUPAP) in 1999 proposed the adoption of the special name “uno” (symbol: U) to represent the number 1 in dimensionless quantities.[6] This symbol is not to be confused with the always-italicized symbol for the variable ‘uncertainty’ (symbol: U). This unit name uno and its symbol could be used in combination with the SI prefixes to express the values of dimensionless quantities which are much less—or even greater—than one.[10]
Common parts-per notations in terms of the uno are given in the table below.
Coefficient | Parts-per example | Uno equiv. | Symbol form | Value of quantity |
---|---|---|---|---|
10−2 | 2% | 2 centiuno | 2 cU | 2 × 10−2 |
10−3 | 2 ‰ | 2 milliuno | 2 mU | 2 × 10−3 |
10−6 | 2 ppm | 2 microuno | 2 µU | 2 × 10−6 |
10−9 | 2 ppb | 2 nanouno | 2 nU | 2 × 10−9 |
10−12 | 2 ppt | 2 picouno | 2 pU | 2 × 10−12 |
In 2004, a report to the International Committee for Weights and Measures (known also by its French-language initials CIPM) stated that response to the proposal of the uno “had been almost entirely negative” and the principal proponent “recommended dropping the idea.”[11] To date, the uno has not been adopted by any standards organization and it appears unlikely it will ever become an officially sanctioned way to express low-value (high-ratio) dimensionless quantities. The proposal was instructive, however, as to the perceived shortcomings of the current options for denoting dimensionless quantities.
Parts-per notation may properly be used only to express true dimensionless quantities; that is, the units of measurement must cancel in expressions like "1 mg/kg" so that the quotients are pure numbers with values less than 1. Mixed-unit quantities such as "a radon concentration of 15 pCi/L" are not dimensionless quantities and may not be expressed using any form of parts-per notation, such as "15 ppt". Other examples of measures that are not dimensionless quantities are as follows:
Note however, that it is not uncommon to express aqueous concentrations—particularly in drinking-water reports intended for the general public—using parts-per notation (2.1 ppm, 0.8 ppb, etc.) and further, for those reports to state that the notations denote milligrams per liter or micrograms per liter. Although "2.1 mg/L" is not a dimensionless quantity, it is assumed in scientific circles that "2.1 mg/kg" (2.1 ppm) is the true measure because one liter of water has a mass of about one kilogram, The goal in all technical writing (including drinking-water reports for the general public) is to clearly communicate to the intended audience with minimal confusion. Drinking water is intuitively a volumetric quantity in the public’s mind so measures of contamination expressed on a per-liter basis are considered to be easier to grasp. Still, it is technically possible, for example, to "dissolve" more than one liter of a very hydrophilic chemical in 1 liter of water; parts-per notation would be confusing when describing its solubility in water (greater than a million parts per million), so one would simply state the volume (or mass) that will dissolve into a liter, instead.
When reporting air-borne rather than water-borne densities, a slightly different convention is used since air is approximately 1000 times less dense than water. In water, 1 µg/m3 is roughly equivalent to parts-per-trillion whereas in air, it is roughly equivalent to parts-per-billion. Note also, that in the case of air, this convention is much less accurate. Whereas one liter of water is almost exactly 1 kg, one cubic meter of air is often taken as 1.143 kg—much less accurate, but still close enough for many practical uses.[citation needed]
|
|
Look up ppm, ppb, ppt, or ppq in Wiktionary, the free dictionary. |
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
リンク元 | 「百万分率」「ppm」 |
関連記事 | 「part」「per」「par」「PER」「pe」 |
テンプレート:Otheruses テンプレート:小文字 ppm(パーツ・パー・ミリオン)は、100万分のいくらであるかという割合を示す単位。主に濃度を表すために用いられるが、不良品発生率などの確率を表すこともある。「parts per million」の頭文字をとったもので、100万分の1の意。百万分率とも。
同様の単位に、ppc(パーセント、parts per cent、100分の1、百分率)、ppb(パーツ・パー・ビリオン、parts per billion、10億分の1、十億分率)、ppt(パーツ・パー・トリリオン、parts per trillion、1兆分の1、一兆分率)などがある。
二酸化窒素などの大気汚染物質をはじめとする公害分野や、食品添加物などの濃度、岩石中の微量元素の組成、半導体中の不純物量を示す目的などで良く用いられる。
気体中の気体については体積比を用い、液体・固体中の液体・固体では重量比を用いるのが一般的である。体積比か重量比かあいまいになる場合は使用しない方がよい。なお、水溶液中の濃度について、「1kg = 1l」と近似し、「mg/l = ppm」として、水質汚濁物質濃度等の単位で用いられることがあるが、公的基準値などでは使用されない。
長さを表す例として、線膨張係数の表記にも使用される。 (例)線膨張係数が8.8ppm/℃と表記されている場合、これは、8.8μm/℃/m(メートル)のことである。
ちなみに、一般の水の遊離残留塩素濃度は約0.4ppm、浄水器を使った場合は約0.1ppmである。
また、原子(分子)の数量の比率か重量の比率かを区別するためにppma(parts per million atomic)もしくはppmw(parts per million weight)の表記が用いられることもある<ref name="NREL_mgSi">シリコン原料の精製に関する論文の例(NREL/SR-520-30716)</ref>。
<references/>
.