テクネチウム99mセスタミビ
WordNet
- a crystalline metallic element not found in nature; occurs as one of the fission products of uranium (同)Tc, atomic number 43
- the 20th letter of the Roman alphabet (同)t
PrepTutorEJDIC
- テクネチウム(マンガン属の元素;化学記号は Tc)
- tritiumの化学記号
- Teachers College 教員養成大学
- technetium の化学記号
UpToDate Contents
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
English Journal
- Radio-UHPLC: a tool for rapidly determining the radiochemical purity of technetium-99m radiopharmaceuticals?
- Kryza D, Janier M.SourceLPMCL UMR 5620 CNRS-Université Claude Bernard Lyon 1, Villeurbanne, France. david.kryza@chu-lyon.fr
- Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.Appl Radiat Isot.2013 Aug;78:72-6. doi: 10.1016/j.apradiso.2013.04.005. Epub 2013 Apr 18.
- Determining the radiochemical purity (RCP) of technetium-99m ((99m)Tc) radiopharmaceuticals using the method described in the package insert is a time-consuming process, requiring particular attention in order to achieve accurate RCP results. The purpose of this study was to evaluate whether radio-u
- PMID 23681064
- Angiographic correlation of myocardial perfusion imaging with half the radiation dose using ordered-subset expectation maximization with resolution recovery software.
- Gutstein A, Navzorov R, Solodky A, Mats I, Kornowski R, Zafrir N.SourceCardiology Department, Beilinson, Rabin Medical Center, Beilinson Campus, Petach Tikva, Israel.
- Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.J Nucl Cardiol.2013 Aug;20(4):539-44. doi: 10.1007/s12350-013-9730-2. Epub 2013 May 24.
- BACKGROUND: We previously described the feasibility of performing myocardial perfusion imaging (MPI) with half the technetium (Tc-99m) activity using ordered-subset expectation maximization with resolution recovery (OSEM-RR) processing. This study sought to assess the accuracy of this technique by c
- PMID 23703379
- The utility and prognostic value of dipyridamole technetium-99m sestamibi myocardial perfusion imaging SPECT in predicting perioperative cardiac events following non-cardiac surgery.
- Asli IN, Shahoseini R, Azizmohammadi Z, Javadi H, Assadi M.SourceDepartment of Nuclear Medicine, Taleghani Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
- Perfusion.Perfusion.2013 Jul;28(4):333-9. doi: 10.1177/0267659113481398. Epub 2013 Mar 12.
- OBJECTIVE: A perioperative cardiac events is one of the most important medical concerns for both surgeons and patients. The purpose of the current study was to determine the prognostic value of myocardial perfusion imaging (MPI), using dipyridamole 99m Tc-MIBI, for the prediction of perioperative ca
- PMID 23482483
Japanese Journal
- Quantitative Assessment of Regional Myocardial Flow Reserve Using Tc-99m-Sestamibi Imaging : Comparison With Results of O-15 Water PET
- Tsukamoto Takahiro,Ito Yoshinori,Noriyasu Kazuyuki,Morita Koichi,Katoh Chietsugu,Okamoto Hiroshi,Tamaki Nagara
- Circulation journal : official journal of the Japanese Circulation Society 69(2), 188-193, 2005-01-20
- … Background The aims of this study were to develop a method for quantitative estimation of the myocardial blood flow index (MBFI) and myocardial flow reserve (MFR) of the whole left ventricle using ^<99m>technetium (Tc-99m)-sestamibi imaging. …
- NAID 110002696069
- Tc-99m-sestamibiを用いた核医学検査手法 Gated SPECTからWashoutまで
- 汲田 伸一郎,趙 圭一,中條 秀信,鳥羽 正浩,福嶋 善光,吉原 尚志,隈崎 達夫,佐野 純子,酒井 俊太,櫻井 薫,佐藤 直樹,田中 啓治,高野 照夫,Kumita Shinichiro,Cho Keichi,Nakajo Hidenobu,Toba Masahiro,Fukushima Yoshimitsu,Yoshihara Naoshi,Kumazaki Tatsuo,Sano Junko,Sakai Shunta,Sakurai Kaoru,Sato Naoki,Tanaka Kenji,Takano Teruo
- 核医学画像診断 18(1), 8-10, 2003-12
- 解説
- NAID 120000817829
Related Links
- Technetium (99m Tc) sestamibi (trade name Cardiolite) is a pharmaceutical agent used in nuclear medicine imaging. The drug is a coordination complex consisting of the radioisotope technetium-99m bound to six (sesta=6 ...
- Technetium TC 99M Sestamibi official prescribing information for healthcare professionals. Includes: indications, dosage, adverse reactions, pharmacology and more. ... Instructions for Preparation Preparation of the Technetium TC ...
★リンクテーブル★
[★]
- 英
- 99mTc-sestamibi, technetium Tc-99m sestamibi, technetium-99m-sestamibi, technetium-99m-MIBI, 99mTc-MIBI
- 同
- テクネチウム99mセスタミビ
- 同
- ヘキサキス(2-メトキシイソブチルイソニトリル)テクネチウム(99mTc) technetium(99mTc) hexakis(2-methoxyisobutyl-isonitrile)
- 商
- カーディオライト
- 関
- テクネチウム99m、心筋血流シンチグラフィ
用途
ヘキサキス(2-メトキシイソブチルイソニトリル)テクネチウム(99mTc)の調製
- 本品に、日局「過テクネチウム酸ナトリウム(99mTc)注射液」185~740MBq(1~3mL)を加えて振り混ぜ、95~99℃で15分間加熱した後、室温で15分間放冷する。
物性
- テトラキス(2-メトキシイソブチルイソニトリル)銅(I)四フッ化ホウ素
- 分子式:C24H44BCuF4N4O4
- 分子量:602.97
CNR
|
RNC-Cu+-CNR・BF4-
|
CNR
CH3
|
R:-CH2-C-OCH3
|
CH3
- ヘキサキス(2-メトキシイソブチルイソニトリル)テクネチウム(99mTc)
- 化学名:Technetium Tc99m Sestamibi (USP)
- 化学式:C36H66N6O6 99mTc
- 式量:777.95
[99mTc-(CNR)6]+
[★]
[★]
[★]
[★]
テクネチウム
- 関
- Tc、technetium 99m