99mテクネチウムセスタミビ
UpToDate Contents
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
English Journal
- Influence of proton-pump inhibitors on stomach wall uptake of 99mTc-tetrofosmin in cadmium-zinc-telluride SPECT myocardial perfusion imaging.
- Mouden M1, Rijkee KS, Schreuder N, Timmer JR, Jager PL.
- Nuclear medicine communications.Nucl Med Commun.2015 Feb;36(2):143-7. doi: 10.1097/MNM.0000000000000222.
- BACKGROUND: Proton-pump inhibitors (PPIs) induce potentially interfering stomach wall activity in single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) with technetium-99m (Tc)-sestamibi. However, no data are available for Tc-tetrofosmin. We assessed the influence of pr
- PMID 25356621
- Preoperative localization and intraoperative parathyroid hormone assay in korean patients with primary hyperparathyroidism.
- Cho E1, Chang JM1, Yoon SY1, Lee GT1, Ku YH1, Kim HI1, Lee MC2, Lee GH2, Kim MJ3.
- Endocrinology and metabolism (Seoul, Korea).Endocrinol Metab (Seoul).2014 Dec 29;29(4):464-9. doi: 10.3803/EnM.2014.29.4.464. Epub 2014 May 27.
- BACKGROUND: The intraoperative parathyroid hormone (IOPTH) assay is widely used in patients with primary hyperparathyroidism (PHPT). We investigated the usefulness of the IOPTH assay in Korean patients with PHPT.METHODS: We retrospectively reviewed the data of 33 patients with PHPT who underwent par
- PMID 25325266
- Clinical application of ultrasound for preparation of 99mTc-sestamibi complex.
- Doroudi A1, Erfani M, Norouzi B, Saadati SM, Kiasat A, Ahmadi F, Etesami B, Baghersad MH.
- Annals of nuclear medicine.Ann Nucl Med.2014 Dec 25. [Epub ahead of print]
- OBJECTIVE: The main aim of this investigation is the clinical application of ultrasound irradiation technique as an alternative method to reconstitute sestamibi kits in comparison of water boiling bath method.METHODS: The 740-3700 MBq (20-100 mCi) 99mTc-MIBI (sestamibi) complex samples were prepar
- PMID 25539995
Japanese Journal
- Comparison of Myocardial Perfusion Imaging Between the New High-Speed Gamma Camera and the Standard Anger Camera
- Tanaka Hirokazu,Chikamori Taishiro,Hida Satoshi,Uchida Kenji,Igarashi Yuko,Yokoyama Tsuyoshi,Takahashi Masaki,Shiba Chie,Yoshimura Mana,Tokuuye Koichi,Yamashina Akira
- Circulation Journal, 2012
- … Methods and Results: The study group consisted of 150 consecutive patients who underwent a 1-day stress-rest 99mTc-sestamibi or tetrofosmin imaging protocol. …
- NAID 130002491255
- Quantification of myocardial perfusion SPECT using freeware package (cardioBull)
- Okuda Koichi,Nakajima Kenichi,Hosoya Tetsuo,Ishikawa Takehiro,Matsuo Shinro,Kawano Masaya,Taki Junichi,Kinuya Seigo
- Annals of nuclear medicine 25(8), 571-579, 2011-10-01
- … Methods: Stress-rest 99mTc-sestamibi myocardial perfusion SPECT was performed in 36 patients with CAD and 35 control patients. …
- NAID 10030232773
- Usefulness of gated SPECT myocardial imaging in evaluation of patients with inferior myocardial infarction
- GROZDIC Isidora,SOBIC-SARANOVIC Dragana,PAVLOVIC Smiljana,ARTIKO Vera,PETRASINOVIC Zorica,JAKSIC Emilija,SARANOVIC Djordjije,OBRADOVIC Vladimir
- Annals of nuclear medicine 25(7), 494-500, 2011-08-01
- NAID 10029525594
Related Links
- Technetium (99m Tc) sestamibi (trade name Cardiolite) is a pharmaceutical agent used in nuclear medicine imaging. The drug is a coordination complex consisting of the radioisotope technetium-99m bound to six (sesta=6 ...
- 99m Tc sestamibi a lipophilic cationic complex of a 99m Tc-labeled isonitrite, used as a radionuclide in several organs (e.g., brain, bone, thyroid, breast) for the detection of cancer, or in the heart for identifying coronary artery ...
Related Pictures
★リンクテーブル★
[★]
- 英
- 99mTc-sestamibi, technetium Tc-99m sestamibi, technetium-99m-sestamibi, technetium-99m-MIBI, 99mTc-MIBI
- 同
- テクネチウム99mセスタミビ
- 同
- ヘキサキス(2-メトキシイソブチルイソニトリル)テクネチウム(99mTc) technetium(99mTc) hexakis(2-methoxyisobutyl-isonitrile)
- 商
- カーディオライト
- 関
- テクネチウム99m、心筋血流シンチグラフィ
用途
ヘキサキス(2-メトキシイソブチルイソニトリル)テクネチウム(99mTc)の調製
- 本品に、日局「過テクネチウム酸ナトリウム(99mTc)注射液」185~740MBq(1~3mL)を加えて振り混ぜ、95~99℃で15分間加熱した後、室温で15分間放冷する。
物性
- テトラキス(2-メトキシイソブチルイソニトリル)銅(I)四フッ化ホウ素
- 分子式:C24H44BCuF4N4O4
- 分子量:602.97
CNR
|
RNC-Cu+-CNR・BF4-
|
CNR
CH3
|
R:-CH2-C-OCH3
|
CH3
- ヘキサキス(2-メトキシイソブチルイソニトリル)テクネチウム(99mTc)
- 化学名:Technetium Tc99m Sestamibi (USP)
- 化学式:C36H66N6O6 99mTc
- 式量:777.95
[99mTc-(CNR)6]+
[★]
- 英
- myocardial perfusion scintigraphy
- 同
- 心筋血流シンチグラフィ、(方法)心筋シンチグラフィ、(図)心筋シンチグラム
- 関
- シンチ、99mTc-心筋血流製剤
- 心筋血流を表す放射性医薬品を用いて心筋を描画する核医学画像診断法。
201Tl=
- 早期像(静注後10分後)、後期像?(3-4時間後) ← 虚血心筋におけるタリウムの再分布を見るため。半減期73hr。放出エネルギー低。解像度が悪い
99mTc
- 肝臓に集積しやすいため投与後30-60分後に撮影。再分布がないので安静時と負荷時の撮影が必要
[★]
- 英
- 99mTc-myocardial perfusion agent
- 同
- テクネチウム-99m-心筋血流製剤
- 肝臓に集積しやすいため投与後30-60分後に撮影。再分布がないので安静時と負荷時の撮影が必要
- タリウム心筋シンチに比べて解像度が高い。
[★]
- 英
- sestamibi
- 同
- MIBI
- 関
- 99mテクネチウムセスタミビ(99mTc-sestamibi, 99mTc-MIBI)