ゼングスタケン・ブレークモア管
WordNet
- ride or float on an inflated tube; "We tubed down the river on a hot summer day"
- conduit consisting of a long hollow object (usually cylindrical) used to hold and conduct objects or liquids or gases (同)tubing
- electronic device consisting of a system of electrodes arranged in an evacuated glass or metal envelope (同)vacuum_tube, thermionic vacuum tube, thermionic_tube, electron_tube, thermionic_valve
- (anatomy) any hollow cylindrical body structure (同)tube-shaped structure
- convey in a tube; "inside Paris, they used to tube mail"
- place or enclose in a tube
- provide with a tube or insert a tube into
- the 2nd letter of the Roman alphabet (同)b
- the blood group whose red cells carry the B antigen (同)type_B, group B
- the amount that a tub will hold; "a tub of water" (同)tubful
- a large open vessel for holding or storing liquids (同)vat
- the 19th letter of the Roman alphabet (同)s
PrepTutorEJDIC
- (金属・ガラス・ゴムなどの)管,筒 / (絵の具・歯みがきなどの)チューブ / 《米》(列車・地下鉄の)トンネル / 《英》地下鉄(《米》subway) / (ラジオ・テレビなどの)真空管(vacuum tube) / (動植物の)管状器官
- 『おけ』,たらい / 《話》'bath 2 / (また tubful)おけ1杯[の量](の…)《+of+名》 / 《話》のろくてぶかっこうな船;《俗》でぶ,太っちょ
- sulfurの化学記号 / {略}South[ern]
- 〈U〉管状の物 / 《集合的に》管類 / 〈C〉(ある長さの1本の)管
UpToDate Contents
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
English Journal
- Sedation Using Propofol Induces Similar Diaphragm Dysfunction and Atrophy during Spontaneous Breathing and Mechanical Ventilation in Rats.
- Bruells CS, Maes K, Rossaint R, Thomas D, Cielen N, Bergs I, Bleilevens C, Weis J, Gayan-Ramirez G.Author information From the Department of Surgical Intensive and Intermediate Care, and Department of Anesthesiology, University Hospital of the RWTH Aachen, University of Excellence, Aachen, Germany (C.S.B.); Fonds voor Wetenschappelijk Onderzoek-Flanders, Laboratory of Pneumology, Katholieke Universiteit Leuven, Leuven, Belgium (K.M.); Department of Anesthesiology, University Hospital of the RWTH Aachen, University of Excellence, Aachen, Germany (R.R., I.B., and C.B.); Laboratory of Pneumology, Katholieke Universiteit Leuven, Leuven, Belgium (D.T., N.C., and G.G.-R.); and Institute of Neuropathology and JARA, Translational Brain Medicine, Aachen; University Hospital of the RWTH Aachen, University of Excellence, Aachen, Germany (J.W.).AbstractBACKGROUND:: Mechanical ventilation is crucial for patients with respiratory failure. The mechanical takeover of diaphragm function leads to diaphragm dysfunction and atrophy (ventilator-induced diaphragmatic dysfunction), with an increase in oxidative stress as a major contributor. In most patients, a sedative regimen has to be initiated to allow tube tolerance and ventilator synchrony. Clinical data imply a correlation between cumulative propofol dosage and diaphragm dysfunction, whereas laboratory investigations have revealed that propofol has some antioxidant properties. The authors hypothesized that propofol reduces markers of oxidative stress, atrophy, and contractile dysfunction in the diaphragm.
- Anesthesiology.Anesthesiology.2014 Jan 7. [Epub ahead of print]
- BACKGROUND:: Mechanical ventilation is crucial for patients with respiratory failure. The mechanical takeover of diaphragm function leads to diaphragm dysfunction and atrophy (ventilator-induced diaphragmatic dysfunction), with an increase in oxidative stress as a major contributor. In most patients
- PMID 24401770
- Background-free solution boron NMR spectroscopy.
- Király P.Author information Institute of Organic Chemistry, Research Centre for Natural Sciences, Hungarian Academy of Sciences, Pusztaszeri út 59-67, H-1025, Budapest, Hungary. p.kiraly@chemres.huAbstractThe appearance of background signals arising from the NMR probe and tube is a well-known problem of boron NMR spectroscopy. Background suppression may be achieved by using DEPTH, which increases the signal-to-background (S/B) ratio. Although, the quality of such spectra is often adequate, but in the case of rapid relaxation broadened resonances (T(1) < 1 ms), the residual background signals may still hamper the interpretation of the spectra. It was observed that the background signals are practically invisible in solution (10) B NMR. The unusual isotopic effect on the (S/B) ratio was interpreted as an inherent consequence of the integer versus half-integer spin of (10) B and (11) B, respectively. The practicability of (10/11) B NMR was compared for a selected set of boron compounds covering the typical range of (S/B) ratio. The application of (11) B is more favourable than (10) B as long as it is possible to achieve the desired spectral quality by using DEPTH. Otherwise, the 'background-free' appearance of (10) B NMR spectra makes (10) B a reasonable alternative of (11) B DEPTH. This was found typical for compounds having relaxation broadened resonances. The variable temperature (VT) NMR study of an adduct formation process was also presented here as an example of the advantage of (10) B over (11) B.
- Magnetic resonance in chemistry : MRC.Magn Reson Chem.2012 Sep;50(9):620-6. doi: 10.1002/mrc.3854. Epub 2012 Aug 5.
- The appearance of background signals arising from the NMR probe and tube is a well-known problem of boron NMR spectroscopy. Background suppression may be achieved by using DEPTH, which increases the signal-to-background (S/B) ratio. Although, the quality of such spectra is often adequate, but in the
- PMID 22865695
- The impact of early percutaneous endoscopic gastrostomy placement on treatment completeness and nutritional status in locally advanced head and neck cancer patients receiving chemoradiotherapy.
- Atasoy BM, Yonal O, Demirel B, Dane F, Yilmaz Y, Kalayci C, Abacioglu U, Imeryuz N.Author information S.B. Marmara Universitesi Pendik Egitim ve Arastirma Hastanesi, Fevzi Cakmak mah. Mimar Sinan cad No 41, Ust Kaynarca Pendik, 34899 Istanbul, Turkey. bmatasoy@yahoo.comAbstractTo investigate the impact of early insertion of percutaneous endoscopic gastrostomy-tube on nutritional status and completeness of concurrent chemotherapy in locally advanced head and neck cancer patients treated with chemoradiotherapy. Twenty-three patients were enrolled into this prospective study. Gastrostomy-tube was inserted in patients before the initiation of chemoradiotherapy. There was not any significant change in nutritional parameters of patients that used their tube during treatment. Despite the grade 3 mucositis, the planned concurrent chemotherapy could be given in 70% of the patients. However, nine patients had weak compliance and their body weight (P = 0.01) and body mass index (P = 0.01) deteriorated in the first 4 weeks of chemoradiotherapy. The completeness of concurrent chemo-rate was 44% in these patients. Toxicity, requiring aggressive supportive care, may limit the chemotherapy part of curative concomitant chemoradiotherapy. By providing adequate enteral nutrition the insertion of gastrostomy-tube can increase the completeness rate of concurrent chemotherapy.
- European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery.Eur Arch Otorhinolaryngol.2012 Jan;269(1):275-82. doi: 10.1007/s00405-010-1477-7. Epub 2011 Apr 7.
- To investigate the impact of early insertion of percutaneous endoscopic gastrostomy-tube on nutritional status and completeness of concurrent chemotherapy in locally advanced head and neck cancer patients treated with chemoradiotherapy. Twenty-three patients were enrolled into this prospective study
- PMID 21472468
Related Links
- S-B tube(Sengstaken-Blakemore double tube): 活動性出血の一時出血に有用 ... 現時点での治療法の選択枝1)としては、食道バルーンタンポナーデ(Sengstaken- Blakemore double tube; SB tube)、薬物療法、内視鏡的硬化療法(endoscopic injection ...
- *SBチューブタイプはSengstaken-Blakemore Tube. で、4ルーメン2バルーンで構成 されており、食道静. 脈瘤止血用です。 *ストマックバルーンチューブタイプは2ルーメン 1バ. ルーンで構成されており、胃静脈瘤止血用です。 *リントンチューブタイプは3 ...
★リンクテーブル★
[★]
- 英
- Sengstaken-Blakemore tube
- 同
- ゼングスタケン・ブレークモア管, ゼングスタケン・ブレークモアチューブ、ゼングスターケン・ブレークモア管, ゼングスターケン・ブレークモアチューブ、セングスターケン・ブレークモア管,セングスターケン・ブレークモアチューブ 、Sengstaken-Blakemoreチューブ Sengstaken-Blakemore管、SBチューブ S-B tube
- 関
- 食道静脈瘤
[show details]
概念
- 食道静脈瘤破裂による出血に対する緊急止血用デバイス。
- 出血により視野が遮られ内視鏡的止血を施行できない場合に用いる、らしい
- 長時間の使用は食道を圧迫障害するために、数時間ごとに減圧する。
参考
- http://img.tfd.com/dorland/tube_Sengstaken-Blakemore.jpg
- http://www.free-ed.net/sweethaven/MedTech/NurseCare/pics/fig91801_07.jpg
[★]
- Mg2+存在下でC3, B, Dが反応してC3bBbとなり、これがC3転換酵素(C3bBb)あるいはC5転換酵素(C3bBb3b)を形成する。これらはP(properdin)と結合して活性化し、それぞれC3、C5を活性化する
[★]
- 関
- canal、duct、ductal、ductus、meatus、pipe、tubal、vas
[★]