133Xeガス吸入法
WordNet
- a way of doing something, especially a systematic way; implies an orderly logical arrangement (usually in steps)
- the act of inhaling; the drawing in of air (or other gases) as in breathing (同)inspiration, aspiration, intake, breathing in
PrepTutorEJDIC
- 〈C〉(特に秩序だった)(…の)『方法』,方式《+『of』+『名』(do『ing』)》 / 〈C〉〈U〉(思考行・行為・行動の)きちょうめんさ;秩序,筋道
- 吸入;〈C〉吸入剤
UpToDate Contents
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
- 1. 吸入麻酔薬:特性と送達inhalation anesthetic agents properties and delivery [show details]
… Inhalation agents are unique in their method of delivery via the lungs as a volume percent of inspired gas, rather than as a dose by weight with intravenous (IV) or oral medications. Inhalation agents …
- 2. 熱、煙または化学的刺激物の吸入傷害inhalation injury from heat smoke or chemical irritants [show details]
… appropriate method of airway management either by endotracheal intubation or placement of a tracheostomy. Endotracheal intubation is frequently needed for supportive therapy in the management of inhalation injury …
- 3. 吸入麻酔薬:臨床作用と臨床使用inhalation anesthetic agents clinical effects and uses [show details]
…hypertension . Effects of inhalation and other anesthetic agents on cerebral physiology are summarized in the table Potent volatile inhalation agents – The potent, halogenated inhalation anesthetics (sevoflurane …
- 4. 成人における吸入器の使用the use of inhaler devices in adults [show details]
… oropharyngeal deposition and improves coordination of actuation and inhalation. DPI and SMI inhalers are additional methods to address actuation-inhalation problems. Inhaled medications can be delivered to patients …
- 5. 新型コロナウイルス感染症(COVID-19):麻酔器による集中治療換気covid 19 intensive care ventilation with anesthesia machines [show details]
… consideration if inhalation anesthetic agents are to be administered using the anesthesia machine. However, gas scavenging is not necessary if inhalation agents are avoided.… removed . Plans should be in place to ventilate the patient while the circuit is emptied. One novel method that has been described is placement of an airway filter casing with a Luer connector in the expiratory …
English Journal
- Hemodynamic etiology of elevated flow velocity and stroke in sickle-cell disease.
- Prohovnik I1, Hurlet-Jensen A, Adams R, De Vivo D, Pavlakis SG.
- Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.J Cereb Blood Flow Metab.2009 Apr;29(4):803-10. doi: 10.1038/jcbfm.2009.6. Epub 2009 Feb 11.
- Elevation of blood flow velocity in the large cerebral vessels is known to be of substantial pathophysiologic and prognostic significance in sickle-cell disease (SCD). Its precise cause is not established, but the two obvious proximal mechanisms are obstructive vascular stenosis and hemodynamic dila
- PMID 19209182
- Assessment of mean transit time in the engrafted lung with 133Xe lung ventilation scintigraphy improves diagnosis of bronchiolitis obliterans syndrome in living-donor lobar lung transplant recipients.
- Shinya T1, Sato S, Kato K, Gobara H, Akaki S, Date H, Kanazawa S.
- Annals of nuclear medicine.Ann Nucl Med.2008 Jan;22(1):31-9. doi: 10.1007/s12149-007-0078-z.
- OBJECTIVE: Staging of bronchiolitis obliterans syndrome (BOS) following lung transplantation is based on declines in forced expiratory volume in 1 s (FEV(1)). The aim of this study was to evaluate the usefulness of (133)Xe ventilation scintigraphy in the early detection of BOS following living-donor
- PMID 18250985
- Characterization of 133Xe gas washout in pulmonary emphysema with dynamic 133Xe SPECT functional images.
- Suga K1, Kawakami Y, Yamashita T, Zaki M, Matsunaga N.
- Nuclear medicine communications.Nucl Med Commun.2006 Jan;27(1):71-80.
- PURPOSE: To characterize regional ventilation impairment of pulmonary emphysema using dynamic 133Xe single photon emission computed tomography (SPECT) functional images, compared with other forms of chronic obstructive pulmonary disease (COPD).METHODS: Dynamic 133Xe SPECT was performed in 34 patient
- PMID 16340726
Japanese Journal
- `133´Xe吸入による非侵襲的脳血流測定法の検討 フーリエ法におけるair passage artifactの影響について:フーリエ法におけるair passage artifactの影響について
- 脳動脈りゅう破裂例の`133´Xe吸入法による脳血流測定
- 被殻出血慢性期例における手術群と非手術群の脳血流量の検討
Related Links
- 1. J Neurosurg. 1984 Sep;61(3):510-4. Cerebral hemodynamics in normal-pressure hydrocephalus. Evaluation by 133Xe inhalation method and dynamic CT study. Tamaki N, Kusunoki T, Wakabayashi T, Matsumoto S. Cerebral ...
- Abstract When the 133Xe inhalation method is employed for measuring regional cerebral blood flow, the arterial 133Xe concentration is usually approximated by the end-tidal air concentration. However, this ...
★リンクテーブル★
[★]
- 英
- 133Xe inhalation method
- 関
- 脳血流測定法、脳血流測定
[★]
- 関
- assay、fashion、law、manner、means、method for measurement、-metry、mode、procedure、process、system、technique、way