- 英
- vascular graft
- 関
- 血管移植
WordNet
- of or relating to or having vessels that conduct and circulate fluids; "vascular constriction"; "a vascular bundle"
- corrective consisting of a replacement for a part of the body (同)prosthetic_device
PrepTutorEJDIC
- (血液・樹液などを運ぶ)管の,導管の,血管の
- 〈U〉人工補綴(ほてい);〈C〉人工補綴物(義足・義歯など)
UpToDate Contents
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
English Journal
- Dyeing and antibacterial activation with methylene blue of a cyclodextrin modified polyester vascular graft.
- Kacem I1, Laurent T, Blanchemain N, Neut C, Chai F, Haulon S, Hildebrand HF, Martel B.
- Journal of biomedical materials research. Part A.J Biomed Mater Res A.2014 Sep;102(9):2942-51. doi: 10.1002/jbm.a.34965. Epub 2013 Oct 1.
- The aim of this study was to develop an antiseptic and blue dyed polyester (PET) vascular graft in order to reach two distinct properties: (i) the prevention of postoperative infections, (ii) the improvement of the graft compatibility with the coelioscopy surgical technique. This work consisted of d
- PMID 24123800
- Clinical Results of Cystic Excision for Popliteal Artery Cystic Adventitial Disease: Long-term Benefits of Preserving the Intact Intima.
- Kikuchi S1, Sasajima T2, Kokubo T3, Koya A1, Uchida H1, Azuma N4.
- Annals of vascular surgery.Ann Vasc Surg.2014 Aug;28(6):1567.e5-8. doi: 10.1016/j.avsg.2014.01.016. Epub 2014 Feb 11.
- Surgical treatment for popliteal artery cystic adventitial disease (PACAD) is still controversial. PACAD often occurs in young or middle-aged adults. Therefore, the maintenance of graft patency for very long periods is a concern if a prosthesis is used. Because the intima is intact in PACAD patients
- PMID 24530570
- The degeneration of biological cardiovascular prostheses under pro-calcific metabolic conditions in a small animal model.
- Assmann A1, Zwirnmann K2, Heidelberg F2, Schiffer F2, Horstkötter K2, Munakata H2, Gremse F3, Barth M2, Lichtenberg A4, Akhyari P2.
- Biomaterials.Biomaterials.2014 Aug;35(26):7416-28. doi: 10.1016/j.biomaterials.2014.05.034. Epub 2014 Jun 7.
- In order to allow for a comparative evaluation of the in vivo degeneration of biological and tissue-engineered heart valves and vascular grafts, a small animal model of accelerated cardiovascular calcification is desired. Wistar rats (n = 102; 6 groups) were fed ad libitum with regular chow and 5
- PMID 24917029
Japanese Journal
- Temporary Extracorporeal Brachio-Femoral Vascular Prosthesis Shunt for Ischemia Prevention in an Operation for Abdominal Aortic and Iliac Aneurysms in a Patient with Marfans Syndrome
- Dregelid Einar
- Annals of Thoracic and Cardiovascular Surgery, 2013
- … In open vascular repair, when prolonged infrarenal aortic clamping can be expected, and collateral perfusion is reduced, the use of a temporary shunt may reduce the risk of ischemic complications. … For the prevention of ischemia during open repair with a bifurcated graft, a temporary extracorporeal brachio-femoral vascular prosthesis shunt was constructed. …
- NAID 130003377844
- Surgical Treatment of an Aneurysm of the Common and Deep Femoral Arteries:A Case Report
- Ogino Takashi,Ohbayashi Tamiyuki,Kaneko Tatsuo [他],Satoh Yasushi,Hasegawa Yutaka,Koyano Tetsuya,Ohki Satoshi,Sakata Kazuhiro,Yamagishi Toshiharu,Hagiwara Shuichi,Ohshima Kiyohiro,Iino Yuichi,Takahashi Toru,Takeyoshi Izumi,Morishita Yasuo
- 北関東医学 62(4), 395-397, 2012-11
- … 61-year-old man with an aneurysm of the common and deep femoral arteries underwent successful vascular reconstruction.The patient presented with localized pain and a rapidly enlarging pulsatile mass in the femoral triangle.A graft was placed from the left common femoral artery to the left superficial and deep femoral arteries.No ischemic symptoms or thrombosis developed postoperatively.Successful reconstruction with a graft is rare in this situation,with less than 30 cases reported in Japan to date.This type of aneurysm is characterized by rapid …
- NAID 120004965219
- Vascular Compliance Changes of the Coronary Vessel Wall After Bioresorbable Vascular Scaffold Implantation in the Treated and Adjacent Segments
- BRUGALETTA Salvatore,GOGAS Bill D.,GARCIA-GARCIA Hector M.,FAROOQ Vasim,GIRASIS Chrysafios,HEO Jung Ho,VAN GEUNS Robert Jan,DE BRUYNE Bernard,DUDEK Dariuz,KOOLEN Jacques,SMITS Pieter,VELDHOF Susan,RAPOZA Richard,ONUMA Yoshinobu,ORMISTON John,SERRUYS Patrick W.
- Circulation journal : official journal of the Japanese Circulation Society 76(7), 1616-1623, 2012-06-25
- … Background: Implantation of a metallic prosthesis creates local stiffness with a subsequent mismatch in the compliance of the vessel wall, disturbances in flow and heterogeneous distribution of wall shear stress. … We sought to analyze the mismatch in vascular compliance after ABSORB implantation and its long-term resolution with bioresorption. …
- NAID 10030503219
Related Links
- The performance of vascular prosthesis is measured, amongst other parameters, by the length of time they remain open. This is called patency. The autogenous grafts, represented by veins and arteries, continue to be the ...
- vascular [vas´ku-ler] pertaining to blood vessels or indicative of a copious blood supply. vas·cu·lar (vas'kyū-lăr), Relating to or containing blood vessels. [L. vasculum, a small vessel, dim. of vas] vascular /vas·cu·lar/ (vas´ku-ler) 1.
★リンクテーブル★
[★]
- 英
- synthetic vascular graft, artificial blood vessel, synthetic vascular prosthesis
- 同
- 合成代用血管、代用血管 vascular prosthesis
[★]
- 関
- brace、prostheses、prosthetic
[★]
- 関
- angio、blood vessel、fibrovascular bundle、vascular bundle、vasculogenic、vein、vessel