- 関
- output
WordNet
- to create or manufacture a specific amount; "the computer is outputting the data from the job Im running"
- the quantity of something (as a commodity) that is created (usually within a given period of time); "production was up in the second quarter" (同)yield, production
- what is produced in a given time period (同)outturn, turnout
- production of a certain amount (同)yield
- of or relating to a systole or happening during a systole
PrepTutorEJDIC
- 生産高 / (コンピューターなどの)アウトプット,出力
UpToDate Contents
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
- 1. 高拍出性心不全 high output heart failure
- 2. 急性冠症候群における急性非代償性心不全の治療 treatment of acute decompensated heart failure in acute coronary syndromes
- 3. 急性非代償性心不全の治療:治療の要素 treatment of acute decompensated heart failure components of therapy
- 4. 運動生理学 exercise physiology
- 5. 心不全または心筋症患者の評価 evaluation of the patient with heart failure or cardiomyopathy
English Journal
- A primary estimation of the cardiometabolic risk by using artificial neural networks.
- Kupusinac A, Doroslovački R, Malbaški D, Srdić B, Stokić E.SourceUniversity of Novi Sad, Faculty of Technical Sciences, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia. Electronic address: kupusinac@gmail.com.
- Computers in biology and medicine.Comput Biol Med.2013 Jul 1;43(6):751-7. doi: 10.1016/j.compbiomed.2013.04.001. Epub 2013 Apr 6.
- Estimation of the cardiometabolic risk (CMR) has a leading role in the early prevention of atherosclerosis and cardiovascular diseases. The CMR estimation can be separated into two parts: primary estimation (PE-CMR) that includes easily-obtained, non-invasive and low-cost diagnostic methods and seco
- PMID 23668351
- In silico study of the haemodynamic effects induced by mechanical ventilation and biventricular pacemaker.
- De Lazzari C, Del Prete E, Genuini I, Fedele F.SourceC.N.R., Institute of Clinical Physiology, U.O.S. of Rome, Italy; National Institute of Cardiovascular Research, Bologna, Italy. Electronic address: claudio.delazzari@ifc.cnr.it.
- Computer methods and programs in biomedicine.Comput Methods Programs Biomed.2013 Jun;110(3):519-27. doi: 10.1016/j.cmpb.2013.02.010. Epub 2013 Mar 19.
- In silico modeling of the cardiovascular system (CVS) can help both in understanding pharmacological or pathophysiological process and in providing information which could not be obtained by means of traditional clinical research methods due to practical or ethical reasons. In this work the numerica
- PMID 23518335
- Haemodynamic monitoring using arterial waveform analysis.
- Chew MS, Aneman A.SourceaDepartment of Anaesthesia and Intensive Care, Hallands Hospital Halmstad bInstitute of Clinical Sciences Malmö, Lund University, Sweden cIntensive Care Unit, Liverpool Hospital, Liverpool BC, New South Wales dUniversity of New South Wales, Sydney, Australia.
- Current opinion in critical care.Curr Opin Crit Care.2013 Jun;19(3):234-41. doi: 10.1097/MCC.0b013e32836091ae.
- PURPOSE OF REVIEW: To describe the theory behind arterial waveform analysis, the different variables that may be obtained using this method, reliability of measurements and their clinical relevance. Areas for future research are identified.RECENT FINDINGS: The precision of cardiac output (CO) measur
- PMID 23549299
Japanese Journal
- EVALUATION OF ARTERIAL CATHETER MANAGEMENT IN VERY PRETERM NEONATES: PERIPHERAL ARTERY VERSUS UMBILICAL ARTERY
- IMAMURA TAKASHI,MOMOI NOBUO,GO HAYATO,OGASAWARA KEI,KANAI YUJI,SATO MAKI,GOTO AYA,HOSOYA MITSUAKI
- FUKUSHIMA JOURNAL OF MEDICAL SCIENCE 58(1), 2012
- … The systolic and diastolic blood pressure (BP) was significantly higher in the peripheral group than in the umbilical group (p=0.03 and p=0.001). … There was a significant relationship between BP at cannulation and urinary output after cannulation for 24 h in the peripheral group (rs=0.49, p=0.03); …
- NAID 130002153554
- Leg Heating Using Far Infra-red Radiation in Patients with Chronic Heart Failure Acutely Improves the Hemodynamics, Vascular Endothelial Function, and Oxidative Stress
- Inoue Shujiro,Takemoto Masao,Chishaki Akiko,Ide Tomomi,Nishizaka Mari,Miyazono Mami,Sawatari Hiroyuki,Sunagawa Kenji
- Internal Medicine 51(17), 2012
- … While the LTT had no significant effects on the heart rate, systolic arterial pressure, and diastolic blood pressure, it increased the cardiac output (mixed venous oxygen saturation; …
- NAID 130002062331
- Evaluation of arterial catheter management in very preterm neonates: peripheral artery versus umbilical artery
- Imamura Takashi,Momoi Nobuo,Go Hayato,Ogasawara Kei,Kanai Yuji,Sato Maki,Goto Aya,Hosoya Mitsuaki
- Fukushima Journal of Medical Science 58(1), 1-8, 2012
- … The systolic and diastolic blood pressure (BP) was significantly higher in the peripheral group than in the umbilical group (p=0.03 and p=0.001). … There was a significant relationship between BP at cannulation and urinary output after cannulation for 24 h in the peripheral group (r_s=0.49, p=0.03); …
- NAID 120004427940
Related Links
- The majority of patients who had an intact ventricular septum and were less than 6 months of age showed normal end-diastolic volumes (LVEDV) and systolic output (LVSO), while patients in this hemodynamic group more than 6 months of ...
Related Pictures
★リンクテーブル★
[★]
- 英
- output、systolic output
- 関
- 結果、産出量、出力、排出量
[★]
- 関
- consequence、excretion、outcome、outflow、product、result、resultant、sequence、systolic output
[★]
- 関
- systole