眼球電図 EOG
WordNet
- select by a vote for an office or membership; "We elected him chairman of the board"
- selected as the best; "an elect circle of artists"; "elite colleges" (同)elite
- choose; "I elected to have my funds deposited automatically"
- elected but not yet installed in office; "the president elect"
PrepTutorEJDIC
- (投票で)〈議長・議員など〉‘を'『選ぶ』,『選挙する』 / 《文》…‘を'選択する;(…すること)‘に'決定する(decide)《+『to』 do》 / 《通例‐electの形で名詞に付けて》(まだ就任していないが)選挙された,当選した / 選ばれた / 《the~》選ばれるに値する人たち,エリート / 《時にthe~》選ばれた者,選民
Wikipedia preview
出典(authority):フリー百科事典『ウィキペディア(Wikipedia)』「2018/03/15 18:20:09」(JST)
[Wiki en表示]
|
This article needs additional citations for verification. Please help improve this article by adding citations to reliable sources. Unsourced material may be challenged and removed. (December 2016) (Learn how and when to remove this template message)
|
"EOG" redirects here. For other uses, see EOG (disambiguation).
Not to be confused with other types of electrography.
Electrooculograms for the left eye (LEOG) and the right eye (REOG) for the period of REM sleep.
Electrooculography |
ICD-9-CM |
95.22 |
MeSH |
D004585 |
[edit on Wikidata]
|
Electrooculography (EOG/E.O.G.) is a technique for measuring the corneo-retinal standing potential that exists between the front and the back of the human eye. The resulting signal is called the electrooculogram. Primary applications are in ophthalmological diagnosis and in recording eye movements. Unlike the electroretinogram, the EOG does not measure response to individual visual stimuli.
To measure eye movement, pairs of electrodes are typically placed either above and below the eye or to the left and right of the eye. If the eye moves from center position toward one of the two electrodes, this electrode "sees" the positive side of the retina and the opposite electrode "sees" the negative side of the retina. Consequently, a potential difference occurs between the electrodes. Assuming that the resting potential is constant, the recorded potential is a measure of the eye's position.
Contents
- 1 Principle
- 2 Ophthalmological diagnosis
- 3 Application in entertainment
- 4 See also
- 5 References
Principle
The eye acts as a dipole in which the anterior pole is positive and the posterior pole is negative.
- Left gaze: the cornea approaches the electrode near the outer canthus of the left eye, resulting in a negative-trending change in the recorded potential difference.
- Right gaze: the cornea approaches the electrode near the inner canthus of the left eye, resulting in a positive-trending change in the recorded potential difference.
Ophthalmological diagnosis
The EOG is used to assess the function of the pigment epithelium. During dark adaptation, resting potential decreases slightly and reaches a minimum ("dark trough") after several minutes. When light is switched on, a substantial increase of the resting potential occurs ("light peak"), which drops off after a few minutes when the retina adapts to the light. The ratio of the voltages (i.e. light peak divided by dark trough) is known as the Arden ratio. In practice, the measurement is similar to eye movement recordings (see above). The patient is asked to switch eye position repeatedly between two points (alternating looking from center to the left and from center to the right). Since these positions are constant, a change in the recorded potential originates from a change in the resting potential.
Application in entertainment
|
This section has multiple issues. Please help improve it or discuss these issues on the talk page. (Learn how and when to remove these template messages)
|
This section does not cite any sources. Please help improve this section by adding citations to reliable sources. Unsourced material may be challenged and removed. (November 2011) (Learn how and when to remove this template message)
|
(Learn how and when to remove this template message)
|
Electrooculography was used by Robert Zemeckis and Jerome Chen, the visual effects supervisor in the movie Beowulf, to enhance the performance capture by correctly animating the eye movements of the actors. The result was an improvement over the technique used for the film The Polar Express.
Electrooculography, in addition to other neuromuscular signals, is used as a computer input method by the Neural Impulse Actuator.
See also
- International Society for Clinical Electrophysiology of Vision
- Nystagmus
- Optokinetic drum
- Orthoptist
References
- Brown, M., Marmor, M. and Vaegan, ISCEV Standard for Clinical Electro-oculography (EOG) (2006), in: Documenta Ophthalmologica, 113:3(205—212)
- Bulling, A. et al.: It's in Your Eyes - Towards Context-Awareness and Mobile HCI Using Wearable EOG Goggles, Proc. of the 10th International Conference on Ubiquitous Computing (UbiComp 2008), pages 84–93, ACM Press, 2008
- Bulling, A. et al.: Robust Recognition of Reading Activity in Transit Using Wearable Electrooculography, Proc. of the 6th International Conference on Pervasive Computing (Pervasive 2008), pages 19–37, Springer, 2008
- Bulling, A. et al.: Wearable EOG goggles: Seamless sensing and context-awareness in everyday environments, Journal of Ambient Intelligence and Smart Environments, 1(2):157-171, 2009
- Bulling, A. et al.: Eye Movement Analysis for Activity Recognition Using Electrooculography, IEEE Transactions on Pattern Analysis and Machine Intelligence, in press
- Bulling, A. et al.: Eye Movement Analysis for Activity Recognition, International Conference on Ubiquitous Computing (UbiComp 2009), pages 41–50, ACM Press, 2009.
Eye surgery and other procedures (ICD-9-CM V3 08–16+95.0–95.2, ICD-10-PCS 08)
|
Adnexa |
Eyelids |
- Blepharoplasty
- East Asian blepharoplasty
- Epicanthoplasty
- Tarsorrhaphy
|
Lacrimal system |
- Dacryocystorhinostomy
- Punctoplasty
|
|
Globe |
Cornea |
- Radial keratotomy
- LASIK
- Keratomileusis
- Epikeratophakia
- Corneal transplantation
- Photorefractive keratectomy
- Intrastromal corneal ring segment
- Corneal collagen cross-linking
|
Iris, ciliary body,
sclera, and anterior chamber |
- Glaucoma surgery: Trabeculectomy
- Iridectomy
|
Lens |
- Phacoemulsification
- Cataract surgery
- Capsulorhexis
|
Retina, choroid,
vitreous, and posterior chamber |
|
Orbit and eyeball |
|
|
Extraocular muscles |
- Harada–Ito procedure
- Strabismus surgery
- Botulinum toxin therapy of strabismus
|
Medical imaging |
- Fluorescein angiography
- Fundus photography
- Corneal topography
- Optical coherence tomography
- Electrodiagnosis: Electrooculography
- Electroretinography
- Electronystagmography
|
Eye examination |
- Gonioscopy
- Dilated fundus examination
- Ocular tonometry
- Ophthalmoscopy
- Retinoscopy
- Color perception test
- Visual field test/Perimetry
|
Radiotherapy |
|
Medical test: Electrodiagnosis
|
Electrocardiography |
- Vectorcardiography
- Magnetocardiography
|
Central nervous system |
- Electroencephalography (Intracranial EEG, stereoelectroencephalography)
- Magnetoencephalography
|
Peripheral nervous system |
- Electromyography (Facial electromyography)
- Nerve conduction study
|
Ears |
|
Eyes |
- Electronystagmography
- Electrooculography
- Electroretinography
|
Digestive system |
- Electrogastrogram
- Magnetogastrography
|
UpToDate Contents
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
English Journal
- Intelligent Multimodal Framework for Human Assistive Robotics Based on Computer Vision Algorithms.
- Ivorra E1, Ortega M2, Catalán JM3, Ezquerro S4, Lledó LD5, Garcia-Aracil N6, Alcañiz M7.
- Sensors (Basel, Switzerland).Sensors (Basel).2018 Jul 24;18(8). pii: E2408. doi: 10.3390/s18082408.
- PMID 30042372
- Head-eye movement of collegiate baseball batters during fastball hitting.
- Higuchi T1, Nagami T2, Nakata H3, Kanosue K4.
- PloS one.PLoS One.2018 Jul 17;13(7):e0200443. doi: 10.1371/journal.pone.0200443. eCollection 2018.
- PMID 30016367
- Feasibility and safety of shared EEG/EOG and vision-guided autonomous whole-arm exoskeleton control to perform activities of daily living.
- Crea S1,2, Nann M3, Trigili E4, Cordella F5, Baldoni A4, Badesa FJ6, Catalán JM7, Zollo L5, Vitiello N4,8, Aracil NG7, Soekadar SR9,10.
- Scientific reports.Sci Rep.2018 Jul 17;8(1):10823. doi: 10.1038/s41598-018-29091-5.
- PMID 30018334
Japanese Journal
- HMDを用いた視線で操作するヒューマンインターフェースの構築
- 田中 智也,寺戸 敏彦
- 電気学会研究会資料. LAV, 光応用・視覚研究会 2011(1), 23-28, 2011-02-24
- NAID 10027800975
- 田中 智也,寺戸 敏彦
- 電気学会研究会資料. LAV, 光応用・視覚研究会 2010(6), 45-50, 2010-02-02
- NAID 10026073215
- 障害(児)者を対象とした生体信号入力デバイスの適応の可能性について
Related Links
- electro-oculogram /elec·tro-oc·u·lo·gram/ (-ok´ūl-o-gram″) the electroencephalographic tracings made while moving the eyes a constant distance between two fixation points, inducing a deflection of fairly constant amplitude ...
- EOG(Electro-oculogram) 眼球には角膜側に正,網膜側に負の電位が帯電しています. 眼窩周辺に電極を貼付することで,眼球変移による電位変化を検出します. このとき計測された電位をEOG(眼電図)と呼びます. 本研究では,この ...
Related Pictures
★リンクテーブル★
[★]
- 英
- electrooculogram electro-oculogram EOG
- ラ
- electro-oculogramma
- 同
- 眼電位図
[★]
- 関
- choose、election、opt、prefer、select
[★]
- 関
- electric、electricity