出典(authority):フリー百科事典『ウィキペディア(Wikipedia)』「2015/08/12 19:46:40」(JST)
A cathode is the electrode from which a conventional current leaves a polarized electrical device. This definition is sometimes remembered using the mnemonic CCD for cathode current departs. A conventional current describes the direction in which positive electronic charges move. Electrons have a negative charge, so the movement of electrons is opposite to the conventional current flow. Consequently, the mnemonic cathode current departs also means that electrons flow into the device's cathode.
Cathode polarity with respect to the anode can be positive or negative; it depends on how the device operates. Although positively charged cations always move towards the cathode (hence their name) and negatively charged anions move away from it, cathode polarity depends on the device type, and can even vary according to the operating mode. In a device which takes energy (such as recharging a battery), the cathode is negative, and in a device which provides energy (such as discharging a battery), the cathode is positive:
An electrode through which current flows the other way (into the device) is termed an anode.
The word was coined in 1834 from the Greek κάθοδος (kathodos), 'descent' or 'way down', by William Whewell, who had been consulted[2] by Michael Faraday over some new names needed to complete a paper on the recently discovered process of electrolysis. In that paper Faraday explained that when an electrolytic cell is oriented so that electric current traverses the "decomposing body" (electrolyte) in a direction "from East to West, or, which will strengthen this help to the memory, that in which the sun appears to move", the cathode is where the current leaves the electrolyte, on the West side: "kata downwards, `odos a way ; the way which the sun sets".[3][4]
The use of 'West' to mean the 'out' direction (actually 'out' → 'West' → 'sunset' → 'down', i.e. 'out of view') may appear unnecessarily contrived. Previously, as related in the first reference cited above, Faraday had used the more straightforward term "exode" (the doorway where the current exits). His motivation for changing it to something meaning 'the West electrode' (other candidates had been "westode", "occiode" and "dysiode") was to make it immune to a possible later change in the direction convention for current, whose exact nature was not known at the time. The reference he used to this effect was the Earth's magnetic field direction, which at that time was believed to be invariant. He fundamentally defined his arbitrary orientation for the cell as being that in which the internal current would run parallel to and in the same direction as a hypothetical magnetizing current loop around the local line of latitude which would induce a magnetic dipole field oriented like the Earth's. This made the internal current East to West as previously mentioned, but in the event of a later convention change it would have become West to East, so that the West electrode would not have been the 'way out' any more. Therefore "exode" would have become inappropriate, whereas "cathode" meaning 'West electrode' would have remained correct with respect to the unchanged direction of the actual phenomenon underlying the current, then unknown but, he thought, unambiguously defined by the magnetic reference. In retrospect the name change was unfortunate, not only because the Greek roots alone do not reveal the cathode's function any more, but more importantly because, as we now know, the Earth's magnetic field direction on which the "cathode" term is based is subject to reversals whereas the current direction convention on which the "exode" term was based has no reason to change in the future.
Since the later discovery of the electron, an easier to remember, and more durably technically correct (although historically false), etymology has been suggested: cathode, from the Greek kathodos, 'way down', 'the way (down) into the cell (or other device) for electrons'.
The flow of electrons is almost always from anode to cathode outside of the cell or device, regardless of the cell or device type and operating mode. An exception is when a diode reverse-conducts, either by accident (breakdown of a normal diode) or by design (breakdown of a Zener diode, photo-current of a photodiode).
In chemistry, a cathode is the electrode of an electrochemical cell at which reduction occurs; a useful mnemonic to remember this is AnOx RedCat (Oxidation at the Anode = Reduction at the Cathode). Another mnemonic is to note the cathode has a 'c', as does 'reduction'. Hence, reduction at the cathode. Perhaps most useful would be to remember cathode corresponds to cation (acceptor) and anode corresponds to anion (acceptor). The cathode can be negative like when the cell is electrolytic (where electrical energy provided to the cell is being used for decomposing chemical compounds); or positive like when the cell is galvanic (where chemical reactions are used for generating electrical energy). The cathode supplies electrons to the positively charged cations which flow to it from the electrolyte (even if the cell is galvanic, i.e., when the cathode is positive and therefore would be expected to repel the positively charged cations; this is due to electrode potential relative to the electrolyte solution being different for the anode and cathode metal/electrolyte systems in a galvanic cell).
The cathodic current, in electrochemistry, is the flow of electrons from the cathode interface to a species in solution. The anodic current is the flow of electrons into the anode from a species in solution.
In an electrolytic cell, the cathode is where the negative polarity is applied to drive the cell. Common results of reduction at the cathode are hydrogen gas or pure metal from metal ions. When discussing the relative reducing power of two redox agents, the couple for generating the more reducing species is said to be more "cathodic" with respect to the more easily reduced reagent.
In a galvanic cell, the cathode is where the positive pole is connected to allow the circuit to be completed: as the anode of the galvanic cell gives off electrons, they return from the circuit into the cell through the cathode.
When metal ions are reduced from ionic solution, they form a pure metal surface on the cathode. Items to be plated with pure metal are attached to and become part of the cathode in the electrolytic solution.
In physics or electronics, a cathode is an electrode that emits electrons into the device. This contrasts with an anode, which accepts electrons.
In a vacuum tube or electronic vacuum system, the cathode is a metal surface which emits free electrons into the evacuated space. Since the electrons are attracted to the positive nuclei of the metal atoms, they normally stay inside the metal and require energy to leave it; this is called the work function of the metal.[5] Cathodes are induced to emit electrons by several mechanisms:[5]
Cathodes can be divided into two types:
A hot cathode is a cathode that is heated by a filament to produce electrons by thermionic emission.[5][9] The filament is a thin wire of a refractory metal like tungsten heated red-hot by an electric current passing through it. Before the advent of transistors in the 1960s, virtually all electronic equipment used hot-cathode vacuum tubes. Today hot cathodes are used in vacuum tubes in radio transmitters and microwave ovens, to produce the electron beams in older cathode ray tube (CRT) type televisions and computer monitors, in x-ray machines, electron microscopes, and fluorescent tubes.
There are two types of hot cathodes:[5]
In order to improve electron emission, cathodes are treated with chemicals, usually compounds of metals with a low work function. Treated cathodes require less surface area, lower temperatures and less power to supply the same cathode current. The untreated tungsten filaments used in early tubes (called "bright emitters") had to be heated to 2500 °F (1400 °C), white-hot, to produce sufficient thermionic emission for use, while modern coated cathodes produce far more electrons at a given temperature so they only have to be heated to 800–1100 °F (425–600 °C)[5][7][10] There are two main types of treated cathodes:[5][9]
This is a cathode that is not heated by a filament. They may emit electrons by field electron emission, and in gas-filled tubes by secondary emission. Some examples are electrodes in neon lights, cold-cathode fluorescent lamps (CCFLs) used as backlights in laptops, thyratron tubes, and Crookes tubes. They do not necessarily operate at room temperature; in some devices the cathode is heated by the electron current flowing through it to a temperature at which thermionic emission occurs. For example, in some fluorescent tubes a momentary high voltage is applied to the electrodes to start the current through the tube; after starting the electrodes are heated enough by the current to keep emitting electrons to sustain the discharge.
Cold cathodes may also emit electrons by photoelectric emission. These are often called photocathodes and are used in phototubes used in scientific instruments and image intensifier tubes used in night vision goggles.
In a semiconductor diode, the cathode is the N–doped layer of the PN junction with a high density of free electrons due to doping, and an equal density of fixed positive charges, which are the dopants that have been thermally ionized. In the anode, the converse applies: It features a high density of free "holes" and consequently fixed negative dopants which have captured an electron (hence the origin of the holes).
When P and N-doped layers are created adjacent to each other, diffusion ensures that electrons flow from high to low density areas: That is, from the N to the P side. They leave behind the fixed positively charged dopants near the junction. Similarly, holes diffuse from P to N leaving behind fixed negative ionised dopants near the junction. These layers of fixed positive and negative charges are collectively known as the depletion layer because they are depleted of free electrons and holes. The depletion layer at the junction is at the origin of the diode's rectifying properties. This is due to the resulting internal field and corresponding potential barrier which inhibit current flow in reverse applied bias which increases the internal depletion layer field. Conversely, they allow it in forwards applied bias where the applied bias reduces the built in potential barrier.
Electrons which diffuse from the cathode into the P-doped layer, or anode, become what are termed "minority carriers" and tend to recombine there with the majority carriers, which are holes, on a timescale characteristic of the material which is the p-type minority carrier lifetime. Similarly, holes diffusing into the N-doped layer become minority carriers and tend to recombine with electrons. In equilibrium, with no applied bias, thermally assisted diffusion of electrons and holes in opposite directions across the depletion layer ensure a zero net current with electrons flowing from cathode to anode and recombining, and holes flowing from anode to cathode across the junction or depletion layer and recombining.
Like a typical diode, there is a fixed anode and cathode in a Zener diode, but it will conduct current in the reverse direction (electrons flow from anode to cathode) if its breakdown voltage or "Zener voltage" is exceeded.
|
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
リンク元 | 「cathode」「カソード」「陰極」「cathodal」 |
.