UpToDate Contents
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
English Journal
- The Optimal Weaning Strategy for Intraaortic Balloon Counterpulsation: Volume-Based Versus Rate-Based Approach in an Animal Model.
- Gelsomino S1, Lozekoot PW2, Lorusso R2, de Jong MJ2, Parise O2, Matteucci F2, Lucà F2, Kumar N2, Romano M3, Gensini GF3, La Meir M4, Maessen JG2.
- The Annals of thoracic surgery.Ann Thorac Surg.2015 Dec 16. pii: S0003-4975(15)01670-7. doi: 10.1016/j.athoracsur.2015.10.010. [Epub ahead of print]
- BACKGROUND: Changes in hemodynamics, coronary circulation, visceral flow, and biochemical marker rate reduction or volume deflation for intraaortic balloon pump discontinuation were assessed.METHODS: Twelve healthy pigs were randomly assigned to two groups, the rate-based (RB, n = 6) and volume-bas
- PMID 26706752
- Comparison of effects of extra-thoracic paraaortic counterpulsation to intraaortic balloon pump on circulatory support in acute heart failure.
- Zhang JM1, Liu XC2, Liu ZG3, Zhao L4, Yang L5, Liu TW6, He GW7,8.
- Journal of cardiothoracic surgery.J Cardiothorac Surg.2015 Nov 24;10(1):173. doi: 10.1186/s13019-015-0349-z.
- BACKGROUND: Previously designed intra-thoracic paraaortic counterpulsation device has limited stroke volume and may depress the lung to cause complications. The purpose of this study was to evaluate the hemodynamic effects of an extra-thoracic paraaortic counterpulsation device (ETPACD) in compariso
- PMID 26602754
- Should We Discontinue Intraaortic Balloon During Cardioplegic Arrest? Our Old But Still Open Question.
- Onorati F1, Faggian G1, Santarpino G2.
- The Annals of thoracic surgery.Ann Thorac Surg.2015 Oct;100(4):1512. doi: 10.1016/j.athoracsur.2015.03.062.
- PMID 26434474
Japanese Journal
- Effects of Intraaortic Balloon Pumping on the Angiographic No-Reflow Phenomenon After Percutaneous Coronary Intervention in Patients With Anterior Myocardial Infarction
- Maekawa Kiyoaki,Kawamoto Kenji,Fuke Soichiro,Yoshioka Ryo,Saito Hironori,Sato Tetsuya,Hioka Toru
- Circulation Journal 70(1), 37-43, 2005-12-20
- … Background The effects of intraaortic balloon pumping (IABP) are considered to be a reduction in myocardial oxygen demand because of systolic left ventricular unloading and an increase in coronary blood flow. … Methods and Results The coronary flow velocity pattern of the left anterior descending artery (LAD) was assessed by transthoracic Doppler echocardiography during IABP counterpulsation, and the effects of IABP were compared between angiographic no-reflow and good reflow patients. …
- NAID 110002978457
- Percutaneous Cardiopulmonary Support Aids Resuscitation From Sustained Ventricular Tachycardia
- Izawa Atsushi,Kinoshita Osamu,Shiba Yuji,Takahashi Wataru,Uchikawa Shin-ichiro,Imamura Hiroshi,Owa Mafumi,Kubo Keishi
- Circulation journal : official journal of the Japanese Circulation Society 67(12), 1061-1063, 2003-11-20
- … the patient was resuscitated by immediate use of percutaneous cardiopulmonary support and intraaortic balloon counterpulsation. …
- NAID 110002666255
- Intraaortic balloon counterpulsation : Outcome in cardiac surgical patients
Related Links
- intraaortic balloon counterpulsation a mechanical intervention by a device surgically placed in the lumen in the proximal aorta that affects deflation and inflation of a balloon, synchronized with the cardiac cycle. This intervention is ...
- Intraaortic balloon pump counterpulsation (IABP) is one type of mechanical hemodynamic support, and it has emerged as the single most widely used circulatory assist device. It is used in a variety of clinical conditions:Cardiogenic ... ...
★リンクテーブル★
[★]