- 関
- differential pressure gauge
WordNet
- relating to or showing a difference; "differential treatment"
- a quality that differentiates between similar things
- involving or containing one or more derivatives; "differential equation"
- a pressure gauge for comparing pressures of a gas
- distinguishing characteristics (especially in different species of a genus)
PrepTutorEJDIC
- 『差別的な』 / 微分の / 差動の / 〈C〉差別額,運賃差 / 〈U〉微分 / 〈C〉〈U〉(また『differential gear』)差動歯車,差動装置
- 流体圧力測定器
- (論理学で)種差(ある種が同じ属の他の種と区別される属性);本質的な相違点
UpToDate Contents
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
- 1. 自動血液分析装置 automated hematology instrumentation
- 2. 腰椎穿刺:小児における適応、禁忌、手技、および合併症 lumbar puncture indications contraindications technique and complications in children
- 3. 線維筋痛症の鑑別診断 differential diagnosis of fibromyalgia
- 4. 重症筋無力症の鑑別診断 differential diagnosis of myasthenia gravis
- 5. 肝肥大:鑑別診断および評価 hepatomegaly differential diagnosis and evaluation
English Journal
- A wet/wet differential pressure sensor for measuring vertical hydraulic gradient.
- Fritz BG1, Mackley RD.Author information 1Pacific Northwest National Laboratory, 902 Battelle Blvd., Richland, WA 99354, USA. Bradley.Fritz@pnl.govAbstractVertical hydraulic gradient is commonly measured in rivers, lakes, and streams for studies of groundwater-surface water interaction. While a number of methods with subtle differences have been applied, these methods can generally be separated into two categories; measuring surface water elevation and pressure in the subsurface separately or making direct measurements of the head difference with a manometer. Making separate head measurements allows for the use of electronic pressure sensors, providing large datasets that are particularly useful when the vertical hydraulic gradient fluctuates over time. On the other hand, using a manometer-based method provides an easier and more rapid measurement with a simpler computation to calculate the vertical hydraulic gradient. In this study, we evaluated a wet/wet differential pressure sensor for use in measuring vertical hydraulic gradient. This approach combines the advantage of high-temporal frequency measurements obtained with instrumented piezometers with the simplicity and reduced potential for human-induced error obtained with a manometer board method. Our results showed that the wet/wet differential pressure sensor provided results comparable to more traditional methods, making it an acceptable method for future use.
- Ground water.Ground Water.2010 Jan-Feb;48(1):117-21. doi: 10.1111/j.1745-6584.2009.00609.x. Epub 2009 Jul 31.
- Vertical hydraulic gradient is commonly measured in rivers, lakes, and streams for studies of groundwater-surface water interaction. While a number of methods with subtle differences have been applied, these methods can generally be separated into two categories; measuring surface water elevation an
- PMID 19664046
- Energetic and structural study of diphenylpyridine isomers.
- Rocha MA1, Gomes LR, Low JN, Santos LM.Author information 1Centro de Investigação em Química, Faculdade de Ciências, Universidade do Porto, R. do Campo Alegre 687, P-4169-007 Porto, Portugal.AbstractThe energetic and structural study of three diphenylpyridine isomers is presented in detail. The three isomers, 2,6-, 2,5-, and 3,5-diphenylpyridines, were synthesized via Suzuki-Miyaura methodology based on palladium catalysis, and the crystal structures of the isomers were obtained by X-ray diffraction. The relative energetic stabilities in the condensed and gaseous phases as well as volatilities and structures of the three studied isomers were evaluated, regarding the position of the phenyl groups relative to the nitrogen atom of the pyridine ring. The temperature, standard molar enthalpies, and entropies of fusion were measured and derived by differential scanning calorimetry. The vapor pressures of the considered isomers were determined by a static apparatus based on a MKS capacitance diaphragm manometer. The standard molar enthalpies, entropies, and Gibbs energies of sublimation, at T = 298.15 K, were derived, and the phase diagram near the triple point coordinates were determined for all isomers. The standard (p(o) = 0.1 MPa) molar enthalpies of combustion of all crystalline isomers were determined, at T = 298.15 K, by static bomb combustion calorimetry. The standard molar enthalpies of formation, in the crystalline and gaseous phases, at T = 298.15 K, were derived. The experimental results for the energetics in the gaseous phase of the three compounds were compared and assessed with the values obtained by ab initio calculations at different levels of theory (DFT and MP2) showing that, at this level of theory, the computational methods underestimate the energetic stability, in the gaseous phase, for these molecules. In order to understand the aromaticity in the central ring of each isomer, calculations of NICS (B3LYP/6-311G++(d,p) level of theory) values on the pyridine ring were also performed.
- The journal of physical chemistry. A.J Phys Chem A.2009 Oct 15;113(41):11015-27. doi: 10.1021/jp903792d.
- The energetic and structural study of three diphenylpyridine isomers is presented in detail. The three isomers, 2,6-, 2,5-, and 3,5-diphenylpyridines, were synthesized via Suzuki-Miyaura methodology based on palladium catalysis, and the crystal structures of the isomers were obtained by X-ray diffra
- PMID 19761229
- Validation of forehead venous pressure as a measure of respiratory effort for the diagnosis of sleep apnea.
- Popovic D1, King C, Guerrero M, Levendowski DJ, Henninger D, Westbrook PR.Author information 1University of Southern California, Los Angeles, CA, USA.AbstractOBJECTIVES: The aim of the study was to validate the measurement of Forehead Venous Pressure derived from a single site on the forehead as an alternative to esophageal manometry and respiratory effort bands in the differential diagnosis of sleep apnea.
- Journal of clinical monitoring and computing.J Clin Monit Comput.2009 Feb;23(1):1-10. doi: 10.1007/s10877-008-9154-8. Epub 2008 Dec 31.
- OBJECTIVES: The aim of the study was to validate the measurement of Forehead Venous Pressure derived from a single site on the forehead as an alternative to esophageal manometry and respiratory effort bands in the differential diagnosis of sleep apnea.METHODS: Fourteen subjects underwent a laborator
- PMID 19116764
Japanese Journal
- 6I1-13 圧力センサを用いた陸上植物の葉の光合成測定 : 差動式装置の開発に向けて(教材開発(1))
- 稲葉 成基,熊崎 裕教,加藤 真二
- 岐阜工業高等専門学校紀要 35, 19-22, 2000-03-01
- … Pa., a diaphragm manometer vibrated photothermally was effective. … According as the pressure incresed, the resonance frequency increased monotonically because of the tensile force of the diaphragm on which differential pressure was applied. …
- NAID 110004649421
Related Links
- DMC differential manometer 差圧測定と、連成圧の測定に威力発揮 標準付属品 特 長 型式構成 上下限の接点出力 及び 接点出力のヒステリシス(不感帯)設定機能を 装備しています。また設定値を常時表示しているため一目で設定値 ...
- differential manometer [‚dif·ə′ren·chəl mə′nam·əd·ər] (engineering) An instrument in which the difference in pressure between two sources is determined from the vertical distance between the surfaces of a liquid in two legs of an erect ...
Related Pictures
★リンクテーブル★
[★]
- 英
- differential pressure gauge、differential manometer
[★]
- 関
- differential manometer
[★]
- 関
- differentially、discriminate、discrimination
[★]
- 関
- haemodynamometer、hemodynamometer、pressure gage、sphygmomanometer