低温電子顕微鏡
- 関
- cryoelectron microscopy
WordNet
- magnifier of the image of small objects; "the invention of the microscope led to the discovery of the cell"
PrepTutorEJDIC
- 『顕微鏡』
UpToDate Contents
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
English Journal
- Development of a novel cryogenic microscope with numerical aperture of 0.9 and its application to photosynthesis research.
- Shibata Y1, Katoh W2, Chiba T3, Namie K3, Ohnishi N4, Minagawa J4, Nakanishi H2, Noguchi T2, Fukumura H3.
- Biochimica et biophysica acta.Biochim Biophys Acta.2014 Jun;1837(6):880-7. doi: 10.1016/j.bbabio.2014.03.006. Epub 2014 Mar 17.
- A novel cryogenic optical-microscope system was developed in which the objective lens is set inside of the cryostat adiabatic vacuum space. Being isolated from the sample when it was cooled, the objective lens was maintained at room temperature during the cryogenic measurement. Therefore, the author
- PMID 24650629
- Mechanosignaling between central apparatus and radial spokes controls axonemal dynein activity.
- Oda T1, Yanagisawa H, Yagi T, Kikkawa M.
- The Journal of cell biology.J Cell Biol.2014 Mar 3;204(5):807-19. doi: 10.1083/jcb.201312014.
- Cilia/flagella are conserved organelles that generate fluid flow in eukaryotes. The bending motion of flagella requires concerted activity of dynein motors. Although it has been reported that the central pair apparatus (CP) and radial spokes (RSs) are important for flagellar motility, the molecular
- PMID 24590175
- A cylindrical specimen holder for electron cryo-tomography.
- Palmer CM1, Löwe J2.
- Ultramicroscopy.Ultramicroscopy.2014 Feb;137:20-9. doi: 10.1016/j.ultramic.2013.10.016. Epub 2013 Nov 13.
- The use of slab-like flat specimens for electron cryo-tomography restricts the range of viewing angles that can be used. This leads to the "missing wedge" problem, which causes artefacts and anisotropic resolution in reconstructed tomograms. Cylindrical specimens provide a way to eliminate the probl
- PMID 24275523
Japanese Journal
- 1P208 クライオ電顕による新鮮な膜細胞骨格のその場構造解析(接着・運動・骨格・伝達・膜)))
- 臼倉 治郎,牧原 正樹,渡辺 崇,田中 信夫,貝渕 弘三
- 生物物理 45(SUPPLEMENT_1), S83, 2005-10-19
- NAID 110004571189
- The structure of cucumber mosaic virus : cryoelectron microscope, X-ray crystallography, and sequence analysis.
Related Links
- Philips CM12 Microscope A 120 kV scope with a tungsten filament electron beam source is used for all our routine transmission electron microscopy services. The microscope is equipped with a Gatan 4k x 2.7k CCD camera (Gatan ...
- With the installation of the FEI Titan Krios in May 2010, the Cryoelectron Microscope Facility joins a select group of state-of-art, high-end cryoelectron microscopy facilities in the world. By minimizing EMI, reducing relative humidity to ...
★リンクテーブル★
[★]
- 英
- cryoelectron microscope
- (道具)cryoelectron microscope、(方法)cryoelectron microscopy
- 関
- 低温電子顕微法、クリオ電子顕微鏡
[★]
低温電子顕微鏡、低温電子顕微法
- 関
- cryo-electron microscopy、cryoelectron microscope
[★]
- 関
- microscopic、microscopical、microscopy