アンダーセンシング
UpToDate Contents
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
English Journal
- Fatal Undersensing of Ventricular Fibrillation due to Intermittent High-Amplitude R Waves.
- Anguera I, Sabaté X, Sugrañes G, Cequier A.SourceCardiovascular Diseases Group (Bellvitge Biomedical Research Institute) IDIBELL, Bellvitge University Hospital-ICS, L'Hospitalet de Llobregat, Barcelona, Spain.
- Pacing and clinical electrophysiology : PACE.Pacing Clin Electrophysiol.2011 Dec 21. doi: 10.1111/j.1540-8159.2011.03270.x. [Epub ahead of print]
- A 48-year-old man was admitted after an episode of aborted sudden death with external defibrillation. An implantable cardioverter defibrillator implanted 2 years before for secondary prevention failed to sense properly an episode of ventricular fibrillation. Interrogation of the device showed large
- PMID 22188442
- Long-term follow-up of DDD and VDD pacing: a prospective non-randomized single-centre comparison of patients with symptomatic atrioventricular block.
- Marchandise S, Scavée C, le Polain de Waroux JB, de Meester C, Vanoverschelde JL, Debbas N.SourceDivision of Cardiology, Department of Cardiovascular Diseases, Cliniques Universitaires St-Luc, Université Catholique de Louvain, Avenue Hippocrate, 10-2888, B-1200 Brussels, Belgium.
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.Europace.2011 Nov 8. [Epub ahead of print]
- AimsThis prospective non-randomized single-centre registry compared clinical outcome, pacing parameters, and long-term survival in patients receiving VDD or DDD pacemaker (PMs) for symptomatic atrioventricular (AV) block.Methods and resultsSingle-lead VDD (n= 166) and DDD (n= 254) PMs were implanted
- PMID 22071380
- Common pitfalls in interpreting pacemaker electrocardiograms in the emergency department.
- Venkatachalam KL.SourceMayo Clinic Jacksonville Florida, Division of Cardiology, Jacksonville, FL, USA. venkat.KL@mayo.edu
- Journal of electrocardiology.J Electrocardiol.2011 Nov-Dec;44(6):616-21. Epub 2011 Sep 9.
- The number of patients receiving pacemakers and defibrillators has grown substantially over the last 20 years. In addition, the complexity and sophistication of these devices have increased, making diagnosis of pacemaker problems using the electrocardiogram (ECG) more difficult for clinicians in the
- PMID 21907995
Japanese Journal
- Decrease in Amplitude of Intracardiac Ventricular Electrogram and Inappropriate Therapy in Patients With an Implantable Cardioverter Defibrillator
- Watanabe Hiroshi,Chinushi Masaomi,Izumi Daisuke,Sato Akinori,Okada Shinsuke,Okamura Kazuki,Komura Satoru,Hosaka Yukio,Furushima Hiroshi,Washizuka Takashi,Aizawa Yoshifusa
- International Heart Journal 47(3), 363-370, 2006
- … A low R-wave can cause not only undersensing of ventricular tachyarrhythmia but also inappropriate discharges due to oversensing of unexpected signals because of its characteristic sensing algorithm. …
- NAID 130000068705
- 上腕運動負荷試験を用いたVDDペースメーカーのoversensingに関する検討
- 平 カヤノ,藤野 彰久,渡辺 達也,荻生 徳寛,芦川 紘一,三次 実,鈴木 均,大和田 尊之,前原 和平,丸山 幸夫
- 不整脈 = Journal of arrhythmia 19(1), 30-37, 2003-01-25
- NAID 10010533110
Related Links
- forum Join the Word of the Day Mailing List For webmasters TheFreeDictionary Google Bing? Word / Article Starts with Ends with Text ... undersensing /un·der·sens·ing/ (-sens″ing) missed sensing of cardiac electrical signals by an ...
- ペースメーカの設定 •変更すべき設定は、ペースメーカ依存の程度、原因 疾患によって異なる。–房室ブロック (AV ブロック ) •モード:VOO が良く使用される •ベーシックレート:自己脈もしくはエスケープ+20ppm ~30ppm
Related Pictures