WordNet
- either of two saclike respiratory organs in the chest of vertebrates; serves to remove carbon dioxide and provide oxygen to the blood
PrepTutorEJDIC
- 《しばしば複数形で》『肺』,肺臓
UpToDate Contents
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
English Journal
- Lung function in patients with lung injury due to household chemical inhalation: Post hoc analysis of a prospective nationwide cohort.
- Kim WY1, Park S1, Kim HJ2, Chae EJ3, Do KH3, Huh JW1, Lim CM1, Koh Y1, Hong SB4.
- Respirology (Carlton, Vic.).Respirology.2016 Oct 12. doi: 10.1111/resp.12918. [Epub ahead of print]
- BACKGROUND AND OBJECTIVE: Inhalation exposure to household chemicals can result in serious health problems, although the long-term outcomes are unclear. We evaluated the changes in lung function after home humidifier disinfectant (HD) exposure.METHODS: This post hoc analysis of a prospective nationw
- PMID 27731912
- Aerosol Delivery Using Jet Nebulizer and Vibrating Mesh Nebulizer During High Frequency Oscillatory Ventilation: An In Vitro Comparison.
- Fang TP1,2, Lin HL3, Chiu SH1, Wang SH1, DiBlasi RM4, Tsai YH5, Fink JB6.
- Journal of aerosol medicine and pulmonary drug delivery.J Aerosol Med Pulm Drug Deliv.2016 Oct;29(5):447-453. Epub 2016 Mar 14.
- BACKGROUND: High frequency oscillatory ventilation (HFOV) is used in critically ill patients with severe hypoxemic respiratory failure. The purpose of this in vitro study was to determine the efficiency of aerosol delivery with different lung parameters during simulated neonatal, pediatric, and adul
- PMID 26974175
- Humidifier disinfectant lung injury, how do we approach the issues?
- Choi JE1, Hong SB2, Do KH3, Kim HJ4,5, Chung S6, Lee E7, Choi J8, Hong SJ1.
- Environmental health and toxicology.Environ Health Toxicol.2016 Aug 29;31:e2016019. eCollection 2016.
- A large portion of the Korean population has been exposed to toxic humidifier disinfectants (HDs), and considering that the majority of the victims are infants, the magnitude of the damage is expected to be considerably larger than what has currently been revealed. The current victims are voicing pr
- PMID 27608716
Japanese Journal
- 人工鼻フィルター(HMEF)が加湿不足あるいは加湿過剰をきたす換気条件に関する定量的研究
- 秋元 郁美,中野 順子,鴨志田 麻実子
- 医療機器学 84(3), 349-353, 2014
- … The experiments with dry gases were performed on the model lung-ventilator system. … The test lung with soaked cotton inside was placed in the incubator where temperature was maintained at 37 °C. …
- NAID 130004696035
- 症例 誘発試験により診断した超音波加湿器による急性過敏性肺炎の1例
Related Links
- humidifier lung, hypersensitivity pneumonitis caused by inhalation of air that has been passed through humidifiers, dehumidifiers, or air conditioners contaminated by any variety of fungi, amebas, or thermophilic bacteria. humidifier lung ...
- Humidifier lung information including symptoms, diagnosis, misdiagnosis, treatment, causes, patient stories, videos, forums, prevention, and prognosis. ... Humidifier lung: Introduction Humidifier lung: Inhalation of humidifier vapors ...
Related Pictures