出典(authority):フリー百科事典『ウィキペディア(Wikipedia)』「2015/05/22 19:32:30」(JST)
In radiology, computer-aided detection (CADe), also called computer-aided diagnosis (CADx), are procedures in medicine that assist doctors in the interpretation of medical images. Imaging techniques in X-ray, MRI, and Ultrasound diagnostics yield a great deal of information, which the radiologist has to analyze and evaluate comprehensively in a short time. CAD systems help scan digital images, e.g. from computed tomography, for typical appearances and to highlight conspicuous sections, such as possible diseases.
CAD is a relatively young interdisciplinary technology combining elements of artificial intelligence and digital image processing with radiological image processing. A typical application is the detection of a tumor. For instance, some hospitals use CAD to support preventive medical check-ups in mammography (diagnosis of breast cancer), the detection of polyps in the colon, and lung cancer.
Computer-aided detection (CADe) systems are usually confined to marking conspicuous structures and sections. Computer-aided diagnosis (CADx) systems evaluate the conspicuous structures. For example, in mammography CAD highlights micro calcification clusters and hyperdense structures in the soft tissue. This allows the radiologist to draw conclusions about the condition of the pathology. Another application is CADq, which quantifies, e.g., the size of a tumor or the tumor's behavior in contrast medium uptake. Computer-aided simple triage (CAST) is another type of CAD, which performs a fully automatic initial interpretation and triage of studies into some meaningful categories (e.g. negative and positive). CAST is particularly applicable in emergency diagnostic imaging, where a prompt diagnosis of critical, life-threatening condition is required.
At the present stage of the technology, CAD cannot and may not substitute the doctor, but rather plays a supporting role. The doctor (generally a radiologist) is always responsible for the final interpretation of a medical image.
CAD is fundamentally based on highly complex pattern recognition. X-ray images are scanned for suspicious structures. Normally a few thousand images are required to optimize the algorithm. Digital image data are copied to a CAD server in a DICOM-format and are prepared and analyzed in several steps.
1. Preprocessing for
2. Segmentation for
3. Structure/ROI (Region of Interest) Analyze Every detected region is analyzed individually for special characteristics:
4. Evaluation / classification After the structure is analyzed, every ROI is evaluated individually (scoring) for the probability of a TP. Therefore the procedures are:
If the detected structures have reached a certain threshold level, they are highlighted in the image for the radiologist. Depending on the CAD system these markings can be permanently or temporary saved. The latter's advantage is that only the markings which are approved by the radiologist are saved. False hits should not be saved, because an examination at a later date becomes more difficult then.
CAD systems seek to highlight suspicious structures. Today's CAD systems cannot detect 100% of pathological changes. The hit rate (sensitivity) can be up to 90% depending on system and application.[1] A correct hit is termed a True Positive (TP), while the incorrect marking of healthy sections constitutes a False Positive (FP). The less FPs indicated, the higher the specificity is. A low specificity reduces the acceptance of the CAD system because the user has to identify all of these wrong hits. The FP-rate in lung overview examinations (CAD Chest) could be reduced to 2 per examination. In other segments (e.g. CT lung examinations) the FP-rate could be 25 or more. In CAST systems the FP rate must be extremely low (less than 1 per examination) to allow a meaningful study triage.
The absolute detection rate of the radiologist is an alternative metric to sensitivity and specificity. Overall, results of clinical trials about sensitivity, specificity, and the absolute detection rate can vary markedly. Each study result depends on its basic conditions and has to be evaluated on those terms. The following facts have a strong influence:
CAD is used in the diagnosis of abnormal brain, breast cancer, lung cancer, colon cancer, prostate cancer, bone metastases, coronary artery disease, congenital heart defect, and Alzheimer's disease.
Genetic pattern search method was applied to identify abnormal brain from normal controls. Its classification accuracy was reported as 95.188%.[2]
CAD is used in screening mammography (X-ray examination of the female breast). Screening mammography is used for the early detection of breast cancer. CAD is especially established in US and the Netherlands and is used in addition to human evaluation, usually by a radiologist. The first CAD system for mammography was developed in a research project at the University of Chicago. Today it is commercially offered by iCAD and Hologic. There are currently some non-commercial projects being developed, such as Ashita Project, a gradient-based screening software by Alan Hshieh, as well. However, while achieving high sensitivities, CAD systems tend to have very low specificity and the benefits of using CAD remain uncertain. Some studies suggest a positive impact on mammography screening programs,[3][4] but others show no improvement.[5][6] A 2008 systematic review on computer-aided detection in screening mammography concluded that CAD does not have a significant effect on cancer detection rate, but does undesirably increase recall rate (i.e. the rate of false positives). However, it noted considerable heterogeneity in the impact on recall rate across studies.[7]
Procedures to evaluate mammography based on magnetic resonance imaging exist too.
In the diagnosis of lung cancer, computed tomography with special three-dimensional CAD systems are established and considered as gold standard.[citation needed] At this a volumetric dataset with up to 3,000 single images is prepared and analyzed. Round lesions (lung cancer, metastases and benign changes) from 1 mm are detectable. Today all well-known vendors of medical systems offer corresponding solutions.
Early detection of lung cancer is valuable. The 5-year-survival-rate of lung cancer has stagnated in the last 30 years and is now at approximately just 15%. Lung cancer takes more victims than breast cancer, prostate cancer and colon cancer together. This is due to the asymptomatic growth of this cancer. In the majority of cases it is too late for a successful therapy if the patient develops first symptoms (e.g. chronic croakiness or hemoptysis). But if the lung cancer is detected early (mostly by chance), there is a survival rate at 47% according to the American Cancer Society.[8] At the same time the standard x-ray-examination of the lung is the most frequently x-ray examination with a 50% share. Indeed the random detection of lung cancer in the early stage (stage 1) in the x-ray image is difficult. It is a fact that round lesions vary from 5–10 mm are easily overlooked.[9] The routine application of CAD Chest Systems may help to detect small changes without initial suspicion. Philips was the first vendor to present a CAD for early detection of round lung lesions on x-ray images.[10]
CAD is available for detection of colorectal polyps in the colon. Polyps are small growths that arise from the inner lining of the colon. CAD detects the polyps by identifying their characteristic "bump-like" shape. To avoid excessive false positives, CAD ignores the normal colon wall, including the haustral folds. In early clinical trials, CAD helped radiologists find more polyps in the colon than they found prior to using CAD.[11][12]
CAD is available for the automatic detection of significant (causing more than 50% stenosis) coronary artery disease in coronary CT angiography (CCTA) studies. A low false positives rate (60-70% specificity per patient)[13][14][15] allows using it as a computer-aided simple triage (CAST) tool distinguishing between positive and negative studies and yielding a preliminary report. This, for example, can be used for chest pain patients' triage in an emergency setting.
Early detection of pathology can be the difference between life and death. CADe can be done by auscultation with a digital stethoscope and specialized software, also known as Computer-aided auscultation. Murmurs, irregular heart sounds, caused by blood flowing through a defective heart, can be detected with high sensitivity and specificity. Computer-aided auscultation is sensitive to external noise and bodily sounds and requires an almost silent environment to function accurately.
CADs can be used to identify subjects with Alzheimer's and mild cognitive impairment from normal elder controls. Kernel support vector machine decision tree [16] is proven to have 80% classification accuracy and cost only 0.022s for online prediction.
CADx is available for nuclear medicine images. Commercial CADx systems for the diagnosis of bone metastases in whole-body bone scans and coronary artery disease in myocardial perfusion images exist.[17]
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
リンク元 | 「コンピュータ診断」「コンピュータ支援診断」 |
関連記事 | 「compute」「diagnosis」「assist」「computer」「assisted」 |
.