エイリアシングアーチファクト
WordNet
- a man-made object taken as a whole (同)artefact
PrepTutorEJDIC
- (天然物と区別して)人工物,加工品;(特に)古代人が使った道具(武器,装飾品)
UpToDate Contents
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
English Journal
- POCS-based reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE): A general algorithm for reducing motion-related artifacts.
- Chu ML1,2, Chang HC2, Chung HW1, Truong TK2,3, Bashir MR3, Chen NK2,3.
- Magnetic resonance in medicine.Magn Reson Med.2015 Nov;74(5):1336-48. doi: 10.1002/mrm.25527. Epub 2014 Nov 13.
- PURPOSE: A projection onto convex sets reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE) is developed to reduce motion-related artifacts, including respiration artifacts in abdominal imaging and aliasing artifacts in interleaved diffusion-weighted imaging.THEORY: Images with reduced a
- PMID 25394325
- Fast image interpolation via random forests.
- Huang JJ1, Siu WC, Liu TR.
- IEEE transactions on image processing : a publication of the IEEE Signal Processing Society.IEEE Trans Image Process.2015 Oct;24(10):3232-45. doi: 10.1109/TIP.2015.2440751.
- This paper proposes a two-stage framework for fast image interpolation via random forests (FIRF). The proposed FIRF method gives high accuracy, as well as requires low computation. The underlying idea of this proposed work is to apply random forests to classify the natural image patch space into num
- PMID 26054066
- Improving GRAPPA reconstruction by frequency discrimination in the ACS lines.
- Aja-Fernández S1, Martín DG2, Tristán-Vega A2, Vegas-Sánchez-Ferrero G2,3.
- International journal of computer assisted radiology and surgery.Int J Comput Assist Radiol Surg.2015 Oct;10(10):1699-710. doi: 10.1007/s11548-015-1172-7. Epub 2015 Mar 26.
- PURPOSE: GRAPPA is a well-known parallel imaging method that recovers the MR magnitude image from aliasing by using a weighted interpolation of the data in k-space. To estimate the optimal reconstruction weights, GRAPPA uses a band along the center of the k-space where the signal is sampled at the N
- PMID 25808257
Japanese Journal
- 北村 一司,紀太 千恵子,林 秀隆 [他],錦 成郎
- 日本放射線技術學會雜誌 67(10), 1284-1291, 2011-10-20
- … We know that computed radiography (CR) has many factors to generate artifacts, such as the over / under shoot, aliasing and more. … Recently, we encountered an artifact, we call a metal artifact, not attributable to any known factors in clinical images. … To elucidate the cause of this artifact, we did some experiments with an in-house phantom. …
- NAID 10030042151
- 4-8 面積比率線形補間法(第4部門 メディア処理2)
- 福田 智教
- 映像情報メディア学会冬季大会講演予稿集 (2010), 4-8-1, 2010-12-14
- … When we scale up pictures, artifact noises(eg. jaggies) are produced by aliasing. …
- NAID 110009598395
- 位相拡散フーリエ法に仮想的パラレルイメージングを適用したエイリアスレス画像再生法の検討
- 伊藤 聡志,川和 康宏,山田 芳文
- Medical imaging technology 28(2), 118-126, 2010-03-25
- NAID 10026248513
Related Links
- aliasing artifact In MRI, superimposition of a tissue image from outside the field of view on the opposite side of the desired image, usually in the phase-encode direction, due to an inadequate number of phase-encoding measurements ...
- ALIASING ARTIFACT Q) What is aliasing? A) The first step in understanding aliasing is to put aside the mathematical concept of aliasing and focus on the intuitive understanding. Basically aliasing refers to seeing what is not really ...
★リンクテーブル★
[★]