WordNet
- measuring instrument for measuring tension or pressure (especially for measuring intraocular pressure in testing for glaucoma)
Wikipedia preview
出典(authority):フリー百科事典『ウィキペディア(Wikipedia)』「2017/12/21 17:26:38」(JST)
[Wiki en表示]
Schiøtz tonometer is an indentation tonometer, used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. The indentation of corneal surface is indirectly proportional to the IOP.
Contents
- 1 Parts
- 2 Eponym
- 3 References
- 4 External links
Parts
The Schiotz tonometer consists of a curved footplate which is placed on the cornea of a supine patient. A weighted plunger attached to the footplate sinks into the cornea. A scale then gives a reading depending on how much the plunger sinks into the cornea, and a conversion table converts the scale reading into IOP measured in mmHg.[1]
Footplates have to be cool, dry and sterilized before use.
Eponym
It was invented by the Norwegian ophthalmologist Hjalmar August Schiøtz, who presented it to the Norwegian Medical Society on the 10th of May 1905.[2][3]
References
- ^ "IOP and Tonometry - EyeWiki". Eyewiki.aao.org. Retrieved 2013-10-02.
- ^ Handley, Neil. "Tonometers".
- ^ "Hjalmar Schiøtz og hans tonometer".
External links
- How to measure intraocular pressure: Schiötz tonometry
UpToDate Contents
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
English Journal
- Intraocular pressure variation during femtosecond laser-assisted cataract surgery using a fluid-filled interface.
- Schultz T, Conrad-Hengerer I, Hengerer FH, Dick HB.SourceCenter for Vision Science, Ruhr University Eye Clinic, Bochum, Germany. tim.schultz@kk-bochum.de
- Journal of cataract and refractive surgery.J Cataract Refract Surg.2013 Jan;39(1):22-7. doi: 10.1016/j.jcrs.2012.10.038.
- PURPOSE: To evaluate intraocular pressure (IOP) during femtosecond laser-assisted cataract surgery using a fluid-filled interface.SETTING: Ruhr University Eye Clinic, Bochum, Germany.DESIGN: Prospective clinical trial.METHODS: The absolute IOP was measured with a modified Schiotz tonometer before an
- PMID 23245360
- Preparation, characterization, and in vivo evaluation of triamcinolone acetonide microspheres after intravitreal administration.
- Zarei-Ghanavati S, Malaekeh-Nikouei B, Pourmazar R, Seyedi S.SourceDepartment of Ophthalmology, Eye Research Center, Khatam-al-Anbia Eye Hospital, Mashhad University of Medical Sciences, Mashhad, Iran.
- Journal of ocular pharmacology and therapeutics : the official journal of the Association for Ocular Pharmacology and Therapeutics.J Ocul Pharmacol Ther.2012 Oct;28(5):502-6. Epub 2012 Apr 26.
- PURPOSE: The aim of this study was to evaluate the intraocular pressure (IOP) increasing effect and bioavailability of triamcinolone acetonide (TA) microspheres, as a novel drug delivery system, after intravitreal administration.METHODS: Microspheres loaded by TA were prepared by the solvent evapora
- PMID 22537291
Japanese Journal
- Comberg眼圧計,Schiotz眼圧計およびDraeger Handapplanation Tonometerによる眼圧計測値の比較検討
- Schiotz氏TonometerとApplanation Tonometerとによる計測値の比較について
- Schiotz眼圧計ならびにApplanation TonometerをもってしたOcular Rigidityの測定成績とその検討
Related Pictures
★リンクテーブル★
[★]
- 英
- Schiotz tonometer
- 同
- シェッツ圧入眼圧計
- 関
- 眼圧計
[★]
- 関
- ophthalmotonometer