強度ヒストグラム
WordNet
- high level or degree; the property of being intense (同)intensiveness
- the amount of energy transmitted (as by acoustic or electromagnetic radiation); "he adjusted the intensity of the sound"; "they measured the stations signal strength" (同)strength, intensity level
- a bar chart representing a frequency distribution; heights of the bars represent observed frequencies
PrepTutorEJDIC
- (感情・行動・熱・色などの)『強烈さ』,熱烈さ,強度
- (統計の)度数分布図,柱状図表
UpToDate Contents
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
English Journal
- Measurement of susceptibility artifacts with histogram-based reference value on magnetic resonance images according to standard ASTM F2119.
- Heinrich A, Teichgräber UK, Güttler FV.
- Biomedizinische Technik. Biomedical engineering.Biomed Tech (Berl).2015 Dec 1;60(6):541-9. doi: 10.1515/bmt-2014-0184.
- OBJECTIVE: The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object,
- PMID 25992509
- Functional Proton MRI in Emphysematous Rats.
- Bianchi A1, Tibiletti M, Kjørstad Å, Birk G, Schad LR, Stierstorfer B, Stiller D, Rasche V.
- Investigative radiology.Invest Radiol.2015 Dec;50(12):812-20. doi: 10.1097/RLI.0000000000000189.
- OBJECTIVE: To demonstrate the feasibility of proton magnetic resonance imaging (MRI) ventilation-related maps in rodents for the evaluation of lung function in the presence of pancreatic porcine elastase (PPE)-induced emphysema.MATERIALS AND METHODS: Twelve rats were equally divided into 3 groups: g
- PMID 26146872
- Robust Intensity Standardization in Brain Magnetic Resonance Images.
- De Nunzio G1,2, Cataldo R3,4, Carlà A3,4.
- Journal of digital imaging.J Digit Imaging.2015 Dec;28(6):727-37. doi: 10.1007/s10278-015-9782-8.
- The paper is focused on a tiSsue-Based Standardization Technique (SBST) of magnetic resonance (MR) brain images. Magnetic Resonance Imaging intensities have no fixed tissue-specific numeric meaning, even within the same MRI protocol, for the same body region, or even for images of the same patient o
- PMID 25708893
Japanese Journal
- 輝度値共起ヒストグラムを用いた計量学習による歩容認証の性能評価 (バイオメトリクス)
- 電子情報通信学会技術研究報告 = IEICE technical report : 信学技報 117(236), 17-22, 2017-10-12
- NAID 40021373851
- SVMに基づく輝度値共起ヒストグラムの計量学習を用いた荷物所持に頑健な歩容認証 (パターン認識・メディア理解)
- 電子情報通信学会技術研究報告 = IEICE technical report : 信学技報 116(528), 23-28, 2017-03-20
- NAID 40021161549
- SVMに基づく輝度値共起ヒストグラムの計量学習を用いた荷物所持に頑健な歩容認証 (バイオメトリクス)
- 電子情報通信学会技術研究報告 = IEICE technical report : 信学技報 116(527), 23-28, 2017-03-20
- NAID 40021160260
Related Links
- Intensity Histogram Common Names: Histogram Brief Description In an image processing context, the histogram of an image normally refers to a histogram of the pixel intensity values. This histogram is a graph showing the number of pixels ...
- Intensity Histogram - Free download as Text file (.txt), Powerpoint Presentation (.ppt), PDF File (.pdf) or view presentation slides online. ... Image Histograms Cumulative histogram Effect of gray-level mapping on histogram Histogram ...
★リンクテーブル★
[★]