出典(authority):フリー百科事典『ウィキペディア(Wikipedia)』「2019/06/19 13:21:22」(JST)
The Standard hydrogen electrode (abbreviated SHE), is a redox electrode which forms the basis of the thermodynamic scale of oxidation-reduction potentials. Its absolute electrode potential is estimated to be 4.44 ± 0.02 V at 25 °C, but to form a basis for comparison with all other electrode reactions, hydrogen's standard electrode potential (E0) is declared to be zero volts at any temperature.[1] Potentials of any other electrodes are compared with that of the standard hydrogen electrode at the same temperature.
Hydrogen electrode is based on the redox half cell:
This redox reaction occurs at a platinized platinum electrode. The electrode is dipped in an acidic solution and pure hydrogen gas is bubbled through it. The concentration of both the reduced form and oxidised form is maintained at unity. That implies that the pressure of hydrogen gas is 1 bar (100 kPa) and the activity coefficent of hydrogen ions in the solution is unity. The activity of hydrogen ions is their effective concentration, which is equal to the formal concentration times the activity coefficient. These unit-less activity coefficients are close to 1.00 for very dilute water solutions, but usually lower for more concentrated solutions. The Nernst equation should be written as:
where:
During the early development of electrochemistry, researchers used the normal hydrogen electrode as their standard for zero potential. This was convenient because it could actually be constructed by "[immersing] a platinum electrode into a solution of 1 N strong acid and [bubbling] hydrogen gas through the solution at about 1 atm pressure". However, this electrode/solution interface was later changed. What replaced it was a theoretical electrode/solution interface, where the concentration of H+ was 1 M, but the H+ ions were assumed to have no interaction with other ions (a condition not physically attainable at those concentrations). To differentiate this new standard from the previous one it was given the name 'Standard Hydrogen Electrode'. [2]
In summary,
The choice of platinum for the hydrogen electrode is due to several factors:
The surface of platinum is platinized (i.e., covered with platinum black) to:
Other metals can be used for building electrodes with a similar function such as the palladium-hydrogen electrode.
Because of the high adsorption activity of the platinized platinum electrode, it's very important to protect electrode surface and solution from the presence of organic substances as well as from atmospheric oxygen. Inorganic ions that can reduce to a lower valency state at the electrode also have to be avoided (e.g., Fe3+, CrO2−
4). A number of organic substances are also reduced by hydrogen at a platinum surface, and these also have to be avoided.
Cations that can reduce and deposit on the platinum can be source of interference: silver, mercury, copper, lead, cadmium and thallium.
Substances that can inactivate ("poison") the catalytic sites include arsenic, sulfides and other sulfur compounds, colloidal substances, alkaloids, and material found in living systems.[4]
The standard redox potential of the deuterium couple is slightly different from that of the proton couple (ca. −0.0044 V vs SHE). Various values in this range have been obtained: −0.0061 V,[5] −0.00431 V,[6] −0.0074 V.
Also difference occurs when hydrogen deuteride is used instead of hydrogen in the electrode.[7]
The scheme of the standard hydrogen electrode:
Wikimedia Commons has media related to Standard hydrogen electrode. |
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.