透析器クリアランス
WordNet
- permission to proceed; "the plane was given clearance to land"
- the distance by which one thing clears another; the space between them
- a medical instrument for separating substances in solution by unequal diffusion through semipermeable membranes (同)dialysis_machine
PrepTutorEJDIC
- 〈U〉〈C〉(…の)取り片付け,除去,掃除《+『of』+『名』》 / 〈U〉〈C〉(積荷の)通関手続き,(船の)出港免状 / (またclearance sale)〈C〉大棚ざらいの売出し / 〈U〉〈C〉(手形の)決済,(小切手の)現金化 / 〈U〉〈C〉(二つの物の間の)あき,余裕;(特に)道路面・川の面から橋げたまでの高さ / 〈U〉〈C〉秘密情報の使用許可;(秘密情報を扱う人の)信頼性調査;公安調査
UpToDate Contents
全文を閲覧するには購読必要です。 To read the full text you will need to subscribe.
English Journal
- Impact of intradialytic exercise intensity on urea clearance in hemodialysis patients.
- Brown PDS1, Rowed K1, Shearer J1,2, MacRae JM3, Parker K4.
- Applied physiology, nutrition, and metabolism = Physiologie appliquee, nutrition et metabolisme.Appl Physiol Nutr Metab.2018 Jan;43(1):101-104. doi: 10.1139/apnm-2017-0460. Epub 2017 Sep 29.
- PMID 28961405
- Comparison of hemodialysis with medium cut-off dialyzer and on-line hemodiafiltration on the removal of small and middle-sized molecules
.
- Belmouaz M, Diolez J, Bauwens M, Duthe F, Ecotiere L, Desport E, Bridoux F.
- Clinical nephrology.Clin Nephrol.2018 Jan;89 (2018)(1):50-56. doi: 10.5414/CN109133
.
- BACKGROUND: Recent data suggest that the use of medium cut-off (MCO) dialyzers in hemodialysis (HD) promotes greater clearance and reduction ratio (RR) for myoglobin and other large-sized molecules than on-line hemodiafiltration (ol-HDF), but its effects on β2-microglobulin are not clear. We compar
- PMID 28853700
- Efficacy and safety of low-dose heparin in hemodialysis.
- Murea M1, Russell GB1, Daeihagh P1, Saran AM1, Pandya K1, Cabrera M1, Burkart JM1, Freedman BI1.
- Hemodialysis international. International Symposium on Home Hemodialysis.Hemodial Int.2018 Jan;22(1):74-81. doi: 10.1111/hdi.12563. Epub 2017 Apr 18.
- PMID 28418614
Japanese Journal
- Effects of Reduced Dialysis Fluid Flow in Hemodialysis
- Effect of blood flow rate on internal filtration in a high-flux dialyzer with polysulfone membrane
- Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs 15(3), 266-271, 2012-09-01
- NAID 10031056182
- Performance of polysulfone membrane dialyzers and dialysate flow pattern
- Clinical and experimental nephrology 10(3), 210-215, 2006-09-01
- NAID 10020573224
Related Links
- Kidney International, Vol. 66 (2004), pp. 2077–2084 Measurement of dialyzer clearance, dialysis time, and body size: Death risk relationships among patients EDMUND G. LOWRIE,ZHENSHENG LI,NORMA OFSTHUN, and J. MICHAEL LAZARUS
- New technology permits direct on-line measurement of average small molecule clearance (Kecn) during each dialysis treatment that can be multiplied by time (t) to give a direct measurement of total treatment dose (Kt). This study evaluated the relationship of measured Kt with death risk.
- mortality. Hemodialysis dose is often judged by indexing the total dose per treatment, taken as the product of dialyzer small molecule (urea) clearance (Ku) and the length of the treatment [time (t)], to an estimate of body size taken as the volume of urea distribution in the body (V) yielding the ratio, Kt/V1.
★リンクテーブル★
[★]
- 関
- dialyses、dialysis
[★]
透析器、ダイアライザー
[★]
クリアランス